UCEPR: Ultrafast localized CEST-spectroscopy with PRESS in phantoms and in vivo
- 29 May 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (5) , 1875-1885
Abstract
Purpose Chemical exchange saturation transfer (CEST) is a contrast mechanism enhancing low‐concentration molecules through saturation transfer from their exchangeable protons to bulk water. Often many scans are acquired to form a Z‐spectrum, making the CEST method time‐consuming. Here, an ultrafast localized CEST‐spectroscopy with PRESS (UCEPR) is proposed to obtain the entire Z‐spectrum of a voxel using only two scans, significantly accelerating CEST. Theory and Methods The approach combines ultrafast nonlocalized CEST spectroscopy with localization using PRESS. A field gradient is applied concurrently with the saturation pulse producing simultaneous saturation of all Z‐spectrum frequencies that are also spatially encoded. A readout gradient during data acquisition resolves the spatial dependence of the CEST responses into frequency. UCEPR was tested on a 3T scanner both in phantoms and in vivo. Results In phantoms, a fast Z‐spectroscopy acquisition of multiple pH‐variant iopamidol samples was achieved with four‐ to seven‐fold acceleration as compared to the conventional CEST methods. In vivo, amide proton transfer (APT) in white matter of healthy human brain was measured rapidly in 48 s and with high frequency resolution (≤ 0.2 ppm). Conclusion Compared with conventional CEST methods, UCEPR has the advantage of rapidly acquiring high‐resolution Z‐spectra. Potential in vivo applications include ultrafast localized Z‐spectroscopy, quantitative, or dynamic CEST studies. Magn Reson Med 75:1875–1885, 2016.Keywords
Funding Information
- the National Institutes of Health (EB-004582)
- Cancer Prevention and Research Institute of Texas (R1107)
This publication has 53 references indexed in Scilit:
- Measuring in vivo tumor pHe with CEST‐FISP MRIMagnetic Resonance in Medicine, 2011
- Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectraJournal of Magnetic Resonance, 2011
- Saturation power dependence of amide proton transfer image contrasts in human brain tumors and strokes at 3 TMagnetic Resonance in Medicine, 2011
- Chemical exchange saturation transfer (CEST): What is in a name and what isn't?Magnetic Resonance in Medicine, 2011
- Differentiation between glioma and radiation necrosis using molecular magnetic resonance imaging of endogenous proteins and peptidesNature Medicine, 2010
- Fast multislice pH‐weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiationMagnetic Resonance in Medicine, 2010
- Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brainMagnetic Resonance in Medicine, 2010
- A concentration-independent method to measure exchange rates in PARACEST agentsMagnetic Resonance in Medicine, 2010
- Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experimentsMagnetic Resonance in Medicine, 2009
- Practical data acquisition method for human brain tumor amide proton transfer (APT) imagingMagnetic Resonance in Medicine, 2008