Development and comparison of an esophageal Doppler monitoring-based treatment algorithm with a heart rate and blood pressure-based treatment algorithm for goal-directed fluid therapy in anesthetized dogs: A pilot study
Open Access
- 3 October 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 9, 1008240
Abstract
The objective of this pilot study was to determine the feasibility of a study comparing the efficacy of an esophageal Doppler monitor (EDM)-based fluid therapy algorithm with a heart rate (HR)- and mean arterial blood pressure (MAP)-based algorithm in reducing hypotension and fluid load in anesthetized dogs. Client-owned dogs undergoing general anesthesia for surgical procedures were randomized to two groups. An EDM probe for monitoring blood flow in the descending aorta was placed in each dog before receiving a crystalloid bolus (5 mL/kg) over 5 min. Fluids were repeated in case of fluid responsiveness defined by increasing Velocity Time Integral (VTI) ≥ 10% in group EDM and by decreasing HR ≥ 5 beats/min and/or increasing MAP ≥ 3 mmHg in group standard. The feasibility outcomes included the proportion of dogs completing the study and the clinical applicability of the algorithms. The clinical outcomes were the total administered fluid volume and the duration of hypotension defined as MAP < 60 mmHg. Data was compared between groups with Mann-Whitney U-test. p < 0.05 were deemed significant. Of 25 dogs screened, 14 completed the study (56%). There were no differences in the proportion of recorded time spent in hypotension in group standard [2 (0–39)% (median (range))] and EDM [0 (0–63) %, p = 1], or the total volume of fluids [standard 8 (5–14) mL/kg/h, EDM 11 (4–20) mL/kg/h, p = 0.3]. This study declined the feasibility of a study comparing the impact of two newly developed fluid therapy algorithms on hypotension and fluid load in their current form. Clinical outcome analyses were underpowered and no differences in treatment efficacy between the groups could be determined. The conclusions drawn from this pilot study provide important information for future study designs.Keywords
This publication has 39 references indexed in Scilit:
- Use of systolic pressure variation to predict the cardiovascular response to mini-fluid challenge in anaesthetised dogsThe Veterinary Journal, 2014
- Optimal perioperative management of arterial blood pressureIntegrated Blood Pressure Control, 2014
- The effect of excess fluid balance on the mortality rate of surgical patients: a multicenter prospective studyCritical Care, 2013
- Relationship between Intraoperative Mean Arterial Pressure and Clinical Outcomes after Noncardiac SurgeryAnesthesiology, 2013
- Influence of an acetate- and a lactate-based balanced infusion solution on acid base physiology and hemodynamics: an observational pilot studyEuropean Journal of Medical Research, 2012
- Which goal for fluid therapy during colorectal surgery is followed by the best outcome: near-maximal stroke volume or zero fluid balance?British Journal of Anaesthesia, 2012
- Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality*Critical Care Medicine, 2011
- Oesophageal DopplerCurrent Opinion in Critical Care, 2009
- Normal Values and Incidence of Cardiorespiratory Complications in Dogs During General Anaesthesia. A Review of 1281 CasesJournal of Veterinary Medicine Series A, 2007
- Incidence of Intraoperative Hypotension as a Function of the Chosen DefinitionAnesthesiology, 2007