Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging
Author:
- 10 September 2018
- journal article
- research article
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 8 (4) , 383-392
Abstract
For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein–Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.Keywords
Funding Information
- Korea Institute of Ocean Science and Technology (PE99672)
This publication has 16 references indexed in Scilit:
- Capabilities of the Monte Carlo Simulation Codes for Modeling of a Small Animal SPECT CameraNuclear Medicine and Molecular Imaging, 2018
- A new approach for multi-channel surface EMG signal simulationBiomedical Engineering Letters, 2017
- Compression induced contrast change in X-ray mammograms: A simulation studyBiomedical Engineering Letters, 2011
- Design Guidelines for a Double Scattering Compton Camera for Prompt-$\gamma$ Imaging During Ion Beam Therapy: A Monte Carlo Simulation StudyIEEE Transactions on Nuclear Science, 2010
- Multiple molecular simultaneous imaging in a live mouse using semiconductor Compton cameraJournal of Analytical Atomic Spectrometry, 2008
- Two approaches to implementing projector–backprojector pairs for 3D reconstruction from Compton scattered dataNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Angular uncertainties due to geometry and spatial resolution in Compton camerasIEEE Transactions on Nuclear Science, 1999
- Multiple Compton scattering gamma ray imaging cameraNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990
- Prototype design of multiple Compton gamma-ray cameraIEEE Transactions on Nuclear Science, 1988
- A new method to measure energy, direction, and polarization of gamma raysNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1987