Abstract
The problem of negative skin friction (NSF) is one of the most common issues in pile foundation design. In this study, a new soil-model apparatus was manufactured to investigate the behavior of a disconnected piled-raft system under static load. The apparatus consists of a steel container (560×560×700 mm), axial loading system (frame and hydraulic jack), and measurement tools such as load cells, LVDTs, reference beams, steel plate, distribution frame, holders, and flexi-force sensors attached to piles. A 75 mm LVDT was placed at the center of the foundation to measure settlements, connected through rods fixed to the top beam of the box. The effect of the sandy cushion layer separating the raft and a single unconnected steel pile was examined in detail through several static load tests applied with the hydraulic jack. The cushion layer thickness varied from 0b to 2.5b (b = 25.4 mm pile diameter), with six tests in total. The soil used was natural sand from central Baghdad, classified as poorly graded (SP). Around the pile, soil was placed in five layers, each 10 cm high with 60% relative density, while the cushion layer was prepared at 75% relative density Using the weight method dry and wet relative density and variable thicknesses. Results showed that drag force developed on the pile during loading, associated with soil settlement. Graphs of drag force versus settlement indicated that at cushion thicknesses of 2 to 2.5b, drag force increased with settlement, while at 0.5 to 1b thicknesses, drag forces reached minimum values under loads ranging from 2 to 2.5 tons.

This publication has 7 references indexed in Scilit: