Stastical Variation of DC Corona Pulse Amplitudes in Point-to-Plane Air Gaps
Authors:
- 1 December 1987
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electrical Insulation
- Vol. EI-22 (6) , 825-829
Abstract
Using a multichannel analyzer, statistical variations of corona pulse amplitudes are studied for positive and negative dc corona in point-to-plane air gaps. It is shown that,en generally, pulse amplitudes follow a Gaussian type of probability distribution. Exceptions to this be havior are observed near the corona onset level, near the pulse-to-glow transition level, or in less nonuniform field gaps. The corona pulse amplitudes are reasonably reproducible for positive corona, whereas, for negative corona, the pulse amplitudes are very sensitive to the applied voltage level and are less reproducible.Keywords
This publication has 1 reference indexed in Scilit:
- Correlation of Radio Noise and Quasi-Peak Measurements to Corona Pulse RandomnessIEEE Transactions on Power Apparatus and Systems, 1969