Evaluation of Anterior and Posterior Corneal Higher Order Aberrations for the Detection of Keratoconus and Suspect Keratoconus
Open Access
- 2 December 2022
- journal article
- research article
- Published by MDPI AG in Tomography
- Vol. 8 (6) , 2864-2873
Abstract
Aim: To investigate the application of anterior and posterior corneal higher-order aberrations (HOAs) in detecting keratoconus (KC) and suspect keratoconus (SKC). Method: A retrospective, case-control study evaluating non-ectatic (normal) eyes, SKC eyes, and KC eyes. The Sirius Scheimpfug (CSO, Italy) analyses was used to measure HOAs of the anterior and posterior corneal surfaces. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated. Results: Two-hundred and twenty eyes were included in the analysis (normal n = 108, SKC n = 42, KC n = 70). Receiver operating characteristic (ROC) curve analysis revealed a high predictive ability for anterior corneal HOAs parameters: the root mean square (RMS) total corneal HOAs, RMS trefoil, and RMS coma to detect keratoconus (AUC > 0.9 for all). RMS Coma (3, ±1) derived from the anterior corneal surface was the parameter with the highest ability to discriminate between suspect keratoconus and normal eyes (AUC = 0.922; cut-off > 0.2). All posterior corneal HOAs parameters were unsatisfactory in discriminating between SKC and normal eyes (AUC < 0.8 for all). However, their ability to detect KC was excellent with AUC of >0.9 for all except RMS spherical aberrations (AUC = 0.846). Conclusions: Anterior and posterior corneal higher-order aberrations can differentiate between keratoconus and normal eyes, with a high level of certainty. In suspect keratoconus disease, however, only anterior corneal HOAs, and in particular coma-like aberrations, are of value. Corneal aberrometry may be of value in screening for keratoconus in populations with a high prevalence of the disease.Keywords
All Related Versions
This publication has 20 references indexed in Scilit:
- Evaluation of Total and Corneal Wavefront High Order Aberrations for the Detection of Forme Fruste KeratoconusInvestigative Ophthalmology & Visual Science, 2012
- Detection of Subclinical Keratoconus by Using Corneal Anterior and Posterior Surface Aberrations and Thickness Spatial ProfilesInvestigative Ophthalmology & Visual Science, 2010
- Evaluating Risk Factors for Ectasia: What is the Goal of Assessing Risk?Journal of Refractive Surgery, 2010
- Keratoconus: Classification scheme based on videokeratography and clinical signsJournal of Cataract & Refractive Surgery, 2009
- Pentacam posterior and anterior corneal aberrations in normal and keratoconic eyesClinical and Experimental Optometry, 2009
- Defining Subclinical Keratoconus Using Corneal First-Surface Higher-Order AberrationsAmerican Journal of Ophthalmology, 2007
- Corneal wavefront aberration measurements to detect keratoconus patientsContact Lens and Anterior Eye, 2005
- Keratoconus: an analysis of corneal asymmetryBritish Journal of Ophthalmology, 2004
- KeratoconusSurvey of Ophthalmology, 1998
- Biomicroscopic Signs and Disease Severity in KeratoconusCornea, 1996