Usage of solar shading devices to improve the thermal comfort in summer in a Romanian PassivHaus
Authors:
- 25 November 2019
- journal article
- research article
- Published by SAGE Publications in SIMULATION
- Vol. 96 (5) , 471-486
Abstract
The global trend is to increase the thermal comfort in all kinds of buildings, residential and non-residential. At the same time, minimization of energy consumption and improved building sustainability must be achieved. Only precise calculations can keep the balance between maximizing comfort and minimizing energy consumption. The PassivHaus (PH) is a special type of building with low heating energy consumption that fulfills special requirements defined by the Passivhaus Institut of Darmstadt, Germany. The PassivHaus concept has been successfully implemented in climates other than that of Germany. However, current practice in Southern European countries shows that PHs may exhibit overheating in the hot season, a phenomenon which is not very often encountered in Germany. Shading devices may be considered in these southern countries to improve the thermal comfort in PHs during summer. A model of the AMVIC PH office building located near Bucharest, Romania, has been developed using Simergy and EnergyPlus software. The model was validated and calibrated using measured data during summer. Measurements have been used to estimate the classical thermal comfort indices such as predicted mean vote and predicted percent of dissatisfied. Simulations have been performed to study the effect on thermal comfort of several shading devices, such as exterior blinds, exterior shades, and overhangs. Exterior blinds and exterior shades are generally more efficient than overhangs when the results are discussed with reference to transmitted solar energy flux through the windows.Keywords
This publication has 35 references indexed in Scilit:
- Overheating in residential passive house: Solution strategies revealed and confirmed through data analysis and simulationsEnergy and Buildings, 2011
- Pneumatic and thermal design procedure and analysis of earth-to-air heat exchangers of registry typeApplied Energy, 2011
- Modeling, validation and time-dependent simulation of the first large passive building in RomaniaRenewable Energy, 2011
- Warm season cooling requirements for passive buildings in Southeastern Europe (Romania)Energy, 2010
- A comparison of global optimization algorithms with standard benchmark functions and real-world applications using EnergyPlusJournal of Building Performance Simulation, 2010
- Contrasting the capabilities of building energy performance simulation programsBuilding and Environment, 2008
- CEPHEUS results: measurements and occupants’ satisfaction provide evidence for Passive Houses being an option for sustainable buildingEnergy Policy, 2006
- Re-inventing air heating: Convenient and comfortable within the frame of the Passive House conceptEnergy and Buildings, 2005
- Evaluation of overheating protection with sun-shading systemsSolar Energy, 2001
- EnergyPlus: creating a new-generation building energy simulation programEnergy and Buildings, 2001