Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI
- 12 August 2014
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 24 (12) , 3289-3299
Abstract
To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV − LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71–0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (−2.6 ± 1.0 %) and PRF (−9.1 ± 2.0 %) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. • 256-slice CT assessment of RV function is highly reproducible in repaired TOF. • Pulmonary regurgitation can be evaluated by biventricular systolic volume difference. • CT overestimates RV volume and underestimates pulmonary regurgitation, compared with MRI.Keywords
This publication has 28 references indexed in Scilit:
- Quantifying Pulmonary Regurgitation and Right Ventricular Function in Surgically Repaired Tetralogy of FallotCirculation: Cardiovascular Imaging, 2012
- Quantification of left and right ventricular function and myocardial mass: Comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRIEuropean Journal of Radiology, 2012
- A Low Tube Voltage Technique Reduces the Radiation Dose at Retrospective ECG-gated Cardiac Computed Tomography for Anatomical and Functional AnalysesAcademic Radiology, 2011
- Assessment of interventricular and right-intraventricular dyssynchrony in patients with surgically repaired tetralogy of Fallot by two-dimensional speckle trackingEuropean Heart Journal - Cardiovascular Imaging, 2010
- Right Heart: Split-Bolus Injection of Diluted Contrast Medium for Visualization at Coronary CT AngiographyRadiology, 2008
- Prospectively Gated Transverse Coronary CT Angiography versus Retrospectively Gated Helical Technique: Improved Image Quality and Reduced Radiation DoseRadiology, 2008
- Comprehensive Cardiac Magnetic Resonance Imaging at 3.0 TeslaInvestigative Radiology, 2006
- In vitro validation of phase‐contrast flow measurements at 3 T in comparison to 1.5 T: Precision, accuracy, and signal‐to‐noise ratiosJournal of Magnetic Resonance Imaging, 2005
- Right Ventricular Function after Pulmonary Valve Replacement in Patients with Tetralogy of FallotRadiology, 2004
- Reoperation in adults with repair of tetralogy of fallot: Indications and outcomesThe Journal of Thoracic and Cardiovascular Surgery, 1999