Upgrade of BL-5C as a highly automated macromolecular crystallography beamline at Pohang Light Source II
- 5 February 2021
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (2) , 602-608
Abstract
BL-5C is an in-vacuum undulator beamline dedicated to macromolecular crystallography (MX) at the 3 GeV Pohang Light Source II in Korea. The beamline delivers X-ray beams with a focal spot size of 200 µm × 40 µm (FWHM, H × V) over the energy range 6.5–16.5 keV. The measured flux is 7 × 1011 photons s−1 at 12.659 keV through an aperture size of 50 µm. The experimental station is newly equipped with the photon-counting detector EIGER 9M, the multi-axis micro-diffractometer MD2, and a robotic sample changer with a high-capacity dewar. These instruments enable the operation of this beamline as an automated MX beamline specialized in X-ray fragment screening. This beamline can collect more than 400 data sets a day without human intervention, and a difference map can be automatically calculated by using the data processing pipeline for ligand or fragment identification.Keywords
Funding Information
- This research was supported by the Bio & Medical Technology Development Program of the National Research Foundation (NRF) funded by the Korean government (MSIT)
This publication has 26 references indexed in Scilit:
- P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusingJournal of Synchrotron Radiation, 2017
- EIGER detector: application in macromolecular crystallographyActa Crystallographica Section D Structural Biology, 2016
- Fully automatic macromolecular crystallography: the impact of MASSIF-1 on the optimum acquisition and quality of dataCrystallography Reviews, 2016
- MASSIF-1: a beamline dedicated to the fully automatic characterization and data collection from crystals of biological macromoleculesJournal of Synchrotron Radiation, 2015
- The use of a mini-κ goniometer head in macromolecular crystallography diffraction experimentsActa Crystallographica Section D Structural Biology, 2013
- MxDCandMxLIVE: software for data acquisition, information management and remote access to macromolecular crystallography beamlinesJournal of Synchrotron Radiation, 2012
- PHENIX: a comprehensive Python-based system for macromolecular structure solutionActa Crystallographica Section D Structural Biology, 2010
- Scaling and assessment of data qualityActa Crystallographica Section D Structural Biology, 2005
- CHOOCH: a program for deriving anomalous-scattering factors from X-ray fluorescence spectraJournal of Applied Crystallography, 2001
- The experimental physics and industrial control system architecture: past, present, and futureNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994