The Photodynamic Bone Stabilization System in the Treatment of Humerus Fractures: A Prospective Clinical Trial
Open Access
- 14 June 2018
- journal article
- Published by Springer Nature in Cureus
- Vol. 10 (6) , e2809
Abstract
Fractures of the proximal humerus are among the most common long-bone fractures and present unique challenges to surgeons. Traditional internal fixation methods, such as intramedullary nails, are associated with drawbacks such as an inability to fully fill the trabecular space and a limited ability to utilize supplemental hardware in many cases. We evaluated the safety and effectiveness of a novel fracture fixation device that utilizes a light-cured monomer to stabilize the fracture in a cohort of patients suffering from humerus fractures. We prospectively collected data from patients being treated surgically for humerus fractures. Fractures were treated using the photodynamic bone stabilization system (PBSS) consisting of a balloon and light-cured monomer. Patients were evaluated at 7-14, 30, 60, 90, 180, and 360 days post-procedure. Primary outcomes included normal and complete radiographic fracture healing. Secondary outcomes included pain (via visual analog scale), function (via the disability of the arm, shoulder, and hand (DASH) and constant shoulder scales), and the rate of complications. A total of 33 patients were included in the intent-to-treat analysis (mean age: 76.6 yrs). Of these patients, 88% demonstrated normal radiographic healing at their 90-, 180-, and 360-day visits. Complete radiographic healing was observed in 81%, 88%, and 96% of patients at 90, 180, and 360 days, respectively. Pain scores decreased significantly at day seven when compared with baseline (28.2+20.9 vs.53.6+32.2, p<0.001) and continued to decrease at the 90-day (24.7+15.5, p<0.001), 180-day (17.8+12.5, p<0.001) and 360-day (6.6+6.7, p<0.001) evaluations. DASH scores demonstrated statistically significant improvements over baseline (65.5+31.5) at 90 (37.0+14.9, p<0.001), 180 (30.6+15.7, p<0.001), and 360 days (23.9+15.0, p<0.001) post-procedure. The procedure-related event rate was 36.4%, with 5 (11.4%) device-related adverse events reported at the one-year follow-up. Our study demonstrates the ability of a novel internal fixation device to safely and effectively treat fractures of the humerus in the elderly population.Keywords
This publication has 30 references indexed in Scilit:
- Current options to surgical treatment in osteoporotic fracturesAging Clinical and Experimental Research, 2013
- Measures of adult pain: Visual Analog Scale for Pain (VAS Pain), Numeric Rating Scale for Pain (NRS Pain), McGill Pain Questionnaire (MPQ), Short‐Form McGill Pain Questionnaire (SF‐MPQ), Chronic Pain Grade Scale (CPGS), Short Form‐36 Bodily Pain Scale (SF‐36 BPS), and Measure of Intermittent and Constant Osteoarthritis Pain (ICOAP)Arthritis Care & Research, 2011
- Outcomes following operative and non-operative management of humeral midshaft fractures: a prospective, observational cohort study of 47 patientsEuropean Journal of Trauma and Emergency Surgery, 2011
- Socioeconomic determinants of disability and depression in patients with rheumatoid arthritisArthritis Care & Research, 2010
- Displaced proximal humeral fractures: an Indian experience with locking platesJournal of Orthopaedic Surgery and Research, 2010
- Complications encountered in proximal humerus fractures treated with locking plate fixationActa Orthopaedica et Traumatologica Turcica, 2010
- Internal fixation of proximal humeral fractures with a Polarus humeral nailJournal of Orthopaedics and Traumatology, 2008
- The treatment of dislocated humeral head fractures with a new proximal intramedullary nail systemInternational Orthopaedics, 2007
- Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled studyInternational Orthopaedics, 2006
- Rigid internal fixation of fractures of the proximal humerus in older patientsThe Journal of Bone and Joint Surgery. British volume, 2000