Evaluation of the BOD POD for Estimating Percent Body Fat in Collegiate Track and Field Female Athletes: A Comparison of Four Methods
Authors:
- Len KravitzLKLen Kravitz
- Donna W LocknerDLDonna W Lockner
- 1 November 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 22 (6) , 1985-1991
Abstract
This investigation examined the accuracy of the BOD POD on a group of Division I collegiate track and field female athletes (N = 30). Hydrostatic weighing (HW) was used as the gold standard method. Body density (Db) values obtained from the BOD POD (Db BP) were compared with those determined by HW (Db HW). Both Db values were converted to percent body fat (%BF) using the Siri equation for comparison. Percent body fat values obtained from the BOD POD (BF BP) were also compared with those obtained from dual-energy X-ray absorptiometry (DXA, BF DXA) and skinfold (SF, BF SF). The validity of the BOD POD was assessed using repeated-measures analysis of variance (ANOVA), and the relationship between the methods was examined through Pearson correlation. Average Db BP was 0.00890 g x cm(-3) lower (p < 0.05) than Db HW, resulting in a significant overestimation of %BF (p < 0.05) by the BOD POD. Values for BFDXA and BFBP also differed significantly (p < 0.05). On the other hand, BFSF and BF BP were not significantly different. The correlation between percent body fat values obtained from HW (BFHW) and BF BP was good (r = 0.88, SEE = 2.30) as well as between BF SF and BF BP (r = 0.85, SEE = 2.05). Conversely, the correlation between BFDXA and BF BP was poor (r = 0.25, SEE = 5.73). The strong correlation between BF BP and BF HW presented here suggests that the BOD POD has the potential to be used as a body composition analysis tool for female athletes. The advantages of the BOD POD over HW encourage further investigation of this instrument. However, the fact that the BOD POD and SF results did not differ significantly might suggest that the SF could be used in its place until a better rate of accuracy for this instrument is established.Keywords
This publication has 11 references indexed in Scilit:
- Air Displacement Plethysmography: Validation in Overweight and Obese SubjectsObesity Research, 2005
- Athletics, perfectionism, and disordered eatingEating and Weight Disorders - Studies on Anorexia, Bulimia and Obesity, 2004
- Comparison of the Bod Pod and dual energy x-ray absorptiometry in menPhysiological Measurement, 2004
- Comparison of Bod Pod?? and DXA in Female Collegiate AthletesMedicine & Science in Sports & Exercise, 2004
- Evaluation of Air Displacement for Assessing Body Composition of Collegiate WrestlersMedicine & Science in Sports & Exercise, 2003
- Use of air displacement plethysmography for estimating body fat in a four-component modelMedicine & Science in Sports & Exercise, 2001
- Evaluation of the BOD POD for estimating percentage body fat in a heterogeneous group of adult humansEuropean Journal of Applied Physiology, 2001
- Body Composition Profiles of Elite American HeptathletesInternational Journal of Sport Nutrition and Exercise Metabolism, 2001
- Validation of air displacement plethysmography for assessing body compositionMedicine & Science in Sports & Exercise, 2000
- Prediction of fat and fat-free mass in male athletes using dual X-ray absorptiometry as the reference methodJournal of Sports Sciences, 2000