Pyrrole‐Based Schiff‐Base Sensor for Copper Ions
- 10 December 2020
- journal article
- research article
- Published by Wiley in ChemistrySelect
- Vol. 5 (46) , 14776-14782
Abstract
A new, simple, and reversible Schiff base, (E)‐N′‐((1H‐pyrrol‐2‐yl) methylene) isonicotinohydrazide (L), has been designed, synthesized, and characterized for its optical and elemental properties. The synthesized sensor, L is then successfully investigated for selective and sensitive detection of Cu +2 ions by the colorimetric and spectroscopic method in an aqueous organic solvent. The sensor L showed high selectivity toward Cu +2 ions over other possible interfering ions (Na + , K + , Ca +2 , Mg +2 ,Co +2 , Ni +2 , Zn +2 , Cd +2 , Pb +2 , Cr +3 , Ag + , Al +3 and Mn +2 ) and in a wide pH range. The detection limit reaches up to 17.6 μM, which is lower than the WHO recommended guidelines for drinking water, while the limit of quantification was found to be 58 μM. The binding mode of complexation between Cu +2 and L was found to be 1 : 1 using Job's plot. For practical usage, the designed sensor (L) is transferred onto paper strips and demonstrated for real sample analysis through naked eye color change.Keywords
This publication has 56 references indexed in Scilit:
- Real-Time Electrochemical Monitoring of Adenosine Triphosphate in the Picomolar to Micromolar Range Using Graphene-Modified ElectrodesAnalytical Chemistry, 2013
- A novel gadolinium ion-selective membrane electrode based on 2-(4-phenyl-1, 3-thiazol-2-yliminomethyl) phenolElectrochimica Acta, 2013
- Biomimetic sensor for certain catecholamines employing copper(II) complex and silver nanoparticle modified glassy carbon paste electrodeBiosensors and Bioelectronics, 2013
- A highly sensitive and selective colorimetric and off–on fluorescent chemosensor for Cu2+ based on rhodamine B derivativeSensors and Actuators B: Chemical, 2011
- Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion–carbon nanotube composite glassy carbon electrodeElectrochimica Acta, 2011
- Comparative studies of neodymium (III)-selective PVC membrane sensorsAnalytica Chimica Acta, 2009
- Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff baseTalanta, 2007
- Aluminum(III) selective potentiometric sensor based on morin in poly(vinyl chloride) matrixTalanta, 2007
- An iron(III) ion-selective sensor based on a μ-bis(tridentate) ligandTalanta, 2007
- Biological inorganic and bioinorganic chemistry of neurodegeneration based on prion and Alzheimer diseasesDalton Transactions, 2004