Effects of temperature, pressure, and carrier gases on the performance of an aerosol particle mass analyser
Open Access
- 9 August 2018
- journal article
- research article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (8) , 4617-4626
Abstract
Effective density is a crucial parameter used to predict the transport behaviour and fate of particles in the atmosphere, and to measure instruments used ultimately in the human respiratory tract (Ristimäki et al., 2002). The aerosol particle mass analyser (APM) was first proposed by Ehara et al. (1996) and is used to determine the effective density of aerosol particles. A compact design (Kanomax APM-3601) was subsequently developed by Tajima et al. (2013). Recently, a growing number of field studies have reported application of the APM, and experimental schemes using the differential mobility analyser alongside the APM have been adopted extensively. However, environmental conditions such as ambient pressure and temperature vary with the experimental location, and this could affect the performance of the APM. Gas viscosity and Cunningham slip factors are parameters associated with temperature and pressure and are included in the APM's classification performance parameter: λ . In this study, the effects of temperature and pressure were analysed through theoretical calculation, and the influence of varying carrier gas was experimentally evaluated. The transfer function and APM operational region were further calculated and discussed to examine their applicability. Based on the theoretical analysis of the APM's operational region, the mass detection limits are changed with the properties of carrier gases under a chosen λ value. Moreover, the detection limit can be lowered when the pressure is reduced, which implies that performance may be affected during field study. In experimental evaluation, air, oxygen, and carbon dioxide were selected to atomize aerosols in the laboratory with the aim of evaluating the effect of gas viscosity on the APM's performance. Using monodisperse polystyrene latex (PSL) spheres with nominal diameters of 50 and 100 nm, the classification performance of the APM was slightly varied with carrier gases, while the classification accuracy was consistently within 10 %.Keywords
All Related Versions
This publication has 40 references indexed in Scilit:
- Deposition of fractal-like soot aggregates in the human respiratory tractJournal of Aerosol Science, 2011
- Measurements of particle masses of inorganic salt particles for calibration of cloud condensation nuclei countersAtmospheric Chemistry and Physics, 2009
- Rapid Characterization of Agglomerate Aerosols by In Situ Mass−Mobility MeasurementsLangmuir, 2009
- Effect of particle mass size distribution on the deposition of aerosols in the human respiratory systemJournal of Aerosol Science, 2002
- The Relationship between Mass and Mobility for Atmospheric Particles: A New Technique for Measuring Particle DensityAerosol Science and Technology, 2002
- Size Distributions of Motor Vehicle Exhaust PM: A Comparison Between ELPI and SMPS MeasurementsAerosol Science and Technology, 2000
- High fractal-like dimension of diesel soot agglomeratesJournal of Aerosol Science, 1998
- Novel method to classify aerosol particles according to their mass-to-charge ratio—Aerosol particle mass analyserJournal of Aerosol Science, 1996
- In situ measurement of size and density of submicron aerosol particlesJournal of Applied Physics, 1995
- Performance of a differential mobility analyzer at different gas compositionsJournal of Aerosol Science, 1992