Postoperative pulmonary and aortic 3D haemodynamics in patients after repair of transposition of the great arteries
Authors:
- 1 September 2013
- journal article
- pediatric
- Published by Springer Nature in European Radiology
- Vol. 24 (1) , 200-208
Abstract
Objectives To characterise aortic and pulmonary haemodynamics and investigate the correlation with post-surgical anatomy in patients with dextro-transposition of the great arteries (d-TGA). Methods Four-dimensional (4D) MRI was performed in 17 patients after switch repair of TGA and 12 healthy controls (age, 11.9 ± 5.4 vs 23.3 ± 1.6 years). Patients were divided according to the pulmonary trunk (TP) position in relation to the ascending aorta (AAo): anterior (n = 10) and right/left anterior position (n = 7). Analysis included visual grading (ranking 0–2) of pulmonary and aortic vortical and helical flow, flow velocity quantification, blood-flow distribution to the right and left pulmonary arteries (flow ratio rPA:lPA), and vessel lumen areas. Results Anterior TP position was associated with increased vortices in six out of ten patients compared with right anterior TP position (one out of seven) and controls (none). Reduced systolic lPA and TP lumina in patients resulted in significantly increased peak systolic velocities (P < 0.001). Flow ratio rPA:lPA was more heterogeneous in patients (rPA:lPA = 1.56 ± 0.78 vs volunteers 1.09 ± 0.15; P < 0.05) with predominant flow to the rPA. Eleven patients presented increased helices in the AAo (grade 1.6). Conclusions Evaluation of post-surgical haemodynamics in TGA patients revealed increased vortical flow for anterior TP position, asymmetric flow and increased systolic flow velocity in the pulmonary arteries owing to reduced vascular lumina. Key Points • 3D phase contrast MRI with velocity encoding (4D MRI) has numerous cardiovascular applications • 4D MRI demonstrates postoperative haemodynamics following surgery for transposition of the great arteries • Flow visualisation depicted enhanced pulmonary vortices in the anterior pulmonary trunk • Narrow pulmonary arterial systolic lumina resulted in increased peak systolic velocitiesKeywords
This publication has 45 references indexed in Scilit:
- Assessment of normal flow patterns in the pulmonary circulation by using 4D magnetic resonance velocity mappingMagnetic Resonance Imaging, 2013
- Bicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending AortaCirculation: Cardiovascular Imaging, 2012
- Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imagingThe Journal of Thoracic and Cardiovascular Surgery, 2012
- Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisitionJournal of Cardiovascular Magnetic Resonance, 2012
- 4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of FallotJournal of Cardiovascular Magnetic Resonance, 2012
- Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulationEuropean Journal of Cardio-Thoracic Surgery, 2011
- Transposition of the great arteriesOrphanet Journal of Rare Diseases, 2008
- Follow-up outcomes 10 years after arterial switch operation for transposition of the great arteries: comparison of cardiological health status and health-related quality of life to those of the a normal reference populationEuropean Journal of Pediatrics, 2007
- Right ventricular hypertrophy and diastolic dysfunction in arterial switch patients without pulmonary artery stenosisHeart, 2006
- Simplified Calculation of Body-Surface AreaNew England Journal of Medicine, 1987