Semimicro Determination of COD Employing Microwave Digestion
Author:
- 1 November 2003
- journal article
- research article
- Published by SAGE Publications in Environmental Engineering Science
- Vol. 20 (6) , 617-626
Abstract
A modified semimicro method is described for determining chemical oxygen demand (COD) employing microwave (MW) digestion (0.5 min exposure at 1,000 W power, and 10 min exposure at 250 W power) with a titration assessment. Composition of reaction mixture was the same as that of the usual reflux method. Determination was performed in glass vessels of original tetrafluoromethoxil containers. Under given conditions dichromate autoreduction was low. A good agreement with the usual reflux method was obtained with selected substances (potassium hydrogen phthalate, glutamic acid, glucose, dodecyl sulphate, where COD-MW/ThOD is 98.9–101.5%). With real samples (municipal sewage, mixed tanning and chemical wastewaters, and treated wastewater from biological treatment plants) the obtained results were also satisfactory (88.0–111.9%).Keywords
This publication has 21 references indexed in Scilit:
- Rapid Determination of Chemical Oxygen Demand (COD) Using Focused Microwave Digestion Followed by a Titrimetric MethodAnalytical Sciences, 2001
- Chemical oxygen demand determination in environmental waters by mixed-acid digestion and single sweep polarographyAnalytica Chimica Acta, 2000
- Rapid determination of chemical oxygen demand by a semi-automated method based on microwave sample digestion, chromium(VI) organic solvent extraction and flame atomic absorption spectrometryAnalytica Chimica Acta, 1998
- Flow injection method for the rapid determination of chemical oxygen demand based on microwave digestion and chromium speciation in flame atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1996
- A Mercury-Free Microwave Method for the Chemical Oxygen Demand Analysis of SewageInternational Journal of Environmental Analytical Chemistry, 1995
- Chemical oxygen demand determination in well and river waters by flow-injection analysis using a microwave oven during the oxidation stepAnalytica Chimica Acta, 1992
- Evaluation of microwave digestion for chemical oxygen demand determinationEnvironmental Technology, 1990
- Determination of low chemical oxygen demand values in water by the dichromate semi-micro methodThe Analyst, 1990
- Chemical oxygen demand (COD) using microwave digestionWater Research, 1989
- Elimination of Chloride Interference in the Chemical Oxygen Demand Test.Analytical Chemistry, 1963