Studies on Ablative Performance of silicone low density ablative material
Preprint
- 3 December 2022
- preprint
- Published by Springer Nature in Research Square
Abstract
In the present studies silicon based low density ablative material has been studied for its ablative performance to protect flight hardware from temperature raised due to aerodynamic forces for longer duration. Ablative properties are estimated by oxyacetylene flame test at 100-120 W/m2 heat flux. The time duration for the flame test is taken 200 sec. The material shows low mass and linear ablation rate with high ablative effectiveness. The degradation kinetics of silicon ablator is studied by Thermo Gravimetric Analysis (TGA) method. Non-isothermal TGA is performed in the temperature range of 30 °C to 900 °C at various heating rates viz. 5, 10, 15 and 20 oC/ min. Knowledge of the kinetic parameters of thermal decomposition is used to predict degradation kinetics of the material at high heating rates which the ablator faces during aerospace applications. During ablation the silicone ablative material consist of a virgin zone, reaction zone and char zone. These are explained by kinetic parameters which are determined with help of free software called Kinetic Calculation.Keywords
All Related Versions
- Version 1, 2022-12-03, Research Square
- Published version: Silicon, 15 (8), 3599.
This publication has 18 references indexed in Scilit:
- Oxidation Behavior of Aerospace Materials in High Enthalpy Flows Using an Oxyacetylene Torch FacilityJournal of the American Ceramic Society, 2015
- ICTAC Kinetics Committee recommendations for collecting experimental thermal analysis data for kinetic computationsThermochimica Acta, 2014
- Compressive char strength of thermoplastic polyurethane elastomer nanocompositesPolymers for Advanced Technologies, 2014
- The kinetic and thermodynamic analyses of non-isothermal degradation process of acrylonitrile–butadiene and ethylene–propylene–diene rubbersComposites Part B: Engineering, 2013
- Experimental Study of Ablative Materials by Oxyacetylene Flame Flow SystemJournal of Propulsion and Power, 2011
- FTIR, AFM and PL properties of thin SiOx films deposited by HFCVDMaterials Science and Engineering: B, 2010
- Thermal properties study on the ablation materials of inorganic silicon compound from organosilicone in high percent conversionChinese Science Bulletin, 2007
- Ablation and thermal degradation behaviour of a composite based on resol type phenolic resin: Process modeling and experimentalPolymer, 2006
- General treatment of the thermogravimetry of polymersJournal of Research of the National Bureau of Standards Section A: Physics and Chemistry, 1966
- A New Method of Analyzing Thermogravimetric DataBulletin of the Chemical Society of Japan, 1965