Accuracy of tidal breathing measurement of floright compared to an ultrasonic flowmeter in infants
- 20 February 2014
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 50 (4) , 380-388
Abstract
Summary: Introduction: Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest‐based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term‐born infants and infants with lung disease by the vest‐based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease.Methods: Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current‐carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest‐based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared.Results: We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest‐based system was significantly lower with a mean difference (95% CI) of −1.33 ml/kg (−1.73; −0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE.Conclusion: FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements. Pediatr Pulmonol. 2015; 50:380–388.Keywords
Funding Information
- Volusense AS, Karihaugveien 89, 1086 Oslo, Norway
This publication has 23 references indexed in Scilit:
- Lung Volume, Breathing Pattern and Ventilation Inhomogeneity in Preterm and Term InfantsPLOS ONE, 2009
- Calibration of respiratory inductance plethysmograph in preterm infants with different respiratory conditionsPediatric Pulmonology, 2008
- Mathematical assessment of qualitative diagnostic calibration for respiratory inductive plethysmographyJournal of Applied Physiology, 2001
- Respiratory inductance plethysmography in healthy infants: a comparison of three calibration methodsEuropean Respiratory Journal, 2000
- Tidal breath analysis for infant pulmonary function testingEuropean Respiratory Journal, 2000
- Tidal breathing parameters in young children: Comparison of measurement by respiratory inductance plethysmography to a facemask pneumotachograph systemPediatric Pulmonology, 1999
- Validation of respiratory inductive plethysmography using the Qualitative Diagnostic Calibration method in anaesthetized infantsEuropean Respiratory Journal, 1998
- Tidal Volume Measurements in Newborns Using Respiratory Inductive PlethysmographyAmerican Review of Respiratory Disease, 1993
- Evaluation of Respiratory Inductive Plethysmography in the Measurement of Breathing Pattern and PEEP-lnduced Changes in Lung VolumeChest, 1992
- Changes in Respiratory Pattern Resulting from the Use of a Facemask to Record Respiration in Newborn InfantsPediatric Research, 1982