Characterization of Bacterial Biofilm Composition in Occluded Plastic Biliary Stents
Authors:
- Victor Kalil FlumignanVFVictor Kalil Flumignan
- Marcelo Palma SirciliMSMarcelo Palma Sircili
- Lígia Garcia GermanoLGLígia Garcia Germano
- Ana Vitoria dos Santos SouzaASAna Vitoria dos Santos Souza
- Nicole Fernandes SilvaNSNicole Fernandes Silva
- Newton Kiyoshi FukumasuNFNewton Kiyoshi Fukumasu
- Raphaela Marques AnjosRARaphaela Marques Anjos
- Jose Pinhata OtochJOJose Pinhata Otoch
- Everson Luiz de Almeida ArtifonEAEverson Luiz de Almeida Artifon
Open Access
- 1 August 2025
- journal article
- research article
- Published by Taylor & Francis in Clinical and Experimental Gastroenterology
- Vol. ume 18, 179-189
Abstract
Purpose: Plastic biliary stents are an effective treatment for biliary obstruction. Despite being resolutive and accessible, they are known to have a low patency rate, estimated at 3 to 6 months. This can be attributed to the formation of bacterial biofilm, which leads to the luminal obstruction of the stent. The aim of this study is to identify the bacterial composition of biofilms from obstructed plastic biliary stents removed through ERCP. Methods: Obstructed plastic biliary stents were retrieved from patients undergoing ERCP. The stents were fragmented into three segments of 2.0 cm each: proximal, medial, and distal. Gram staining was performed on each fragment, followed by assessment using optical microscopy. Subsequently, 4 μm cross-sections were made of each fragment, with subsequent analysis by confocal microscopy. The material from the inside of the stents was also placed in culture medium and colony-forming units were counted. Results: Optical microscopy and analysis by confocal microscopy showed a seemingly higher number of bacterial colonies in the distal portion of the stents compared to the proximal and medial regions. A greater presence of bacteria in the distal segments of the stents was confirmed, with growth reaching up to 1014, while growth in the proximal and medial segments was only observed up to 109 and 108, respectively. Biochemical identification using Gram staining identified both Gram-positive and Gram-negative species: Enterococcus faecium; Aeromonas hydrophila/caviae; Escherichia coli; Enterobacter cloacae; Citrobacter freundii; Klebsiella oxytoca; Proteus vulgaris; Proteus mirabilis; Pantoea sp; Morganella morganii. Conclusion: The composition of the biofilm in biliary stents confirmed to be polymicrobial. The distal portion of the stents is likely the most frequent site of obstruction. New strategies, such as the development and improvement of plastic stents, should be considered to slow this growth and enhance permeability.Keywords
This publication has 19 references indexed in Scilit:
- A review on antimicrobial strategies in mitigating biofilm-associated infections on medical implantsCurrent Research in Microbial Sciences, 2024
- Antimicrobial peptides: A small molecule for sustainable healthcare applicationsMedicine in Microecology, 2023
- Association of diverse bacterial communities in human bile samples with biliary tract disorders: a survey using culture and polymerase chain reaction-denaturing gradient gel electrophoresis methodsEuropean Journal of Clinical Microbiology & Infectious Diseases, 2016
- Silver-nanoparticle-coated biliary stent inhibits bacterial adhesion in bacterial cholangitis in swineHepatobiliary & Pancreatic Diseases International, 2016
- Pancreatic and biliary stentsGastrointestinal Endoscopy, 2013
- Why Do Bilioduodenal Plastic Stents Become Occluded? A Clinical and Pathological Investigation on 100 Consecutive PatientsEndoscopy, 2001
- Preventing biliary stent occlusionGastrointestinal Endoscopy, 2000
- A Prospective Randomized Trial of Teflon Versus Polyethylene Stents for Distal Malignant Biliary ObstructionEndoscopy, 1998
- Prolonged Patency with a New-Design Teflon Biliary ProsthesisEndoscopy, 1994
- The role of bacteria in the blockage of biliary stentsGastrointestinal Endoscopy, 1988