Flash glucose monitoring in type 1 diabetes: A comparison with self‐monitoring blood glucose
Open Access
- 6 February 2020
- journal article
- research article
- Published by Wiley in Journal of Diabetes Investigation
- Vol. 11 (5) , 1222-1229
Abstract
Aims/Introduction: A flash glucose monitoring (FGM) system has become available. To clarify the relationship between FGM and self‐monitoring blood glucose (SMBG) values, we compared the two values after simultaneous measurement in Japanese patients with type 1 diabetes, under daily life settings.Materials and Methods: A total of 20 outpatients with type 1 diabetes were analyzed. When FGM and SMBG were carried out simultaneously (within ±3 min), the values were adopted and each FGM value was matched and compared with the corresponding SMBG value. In addition, we analyzed other cases of simultaneity defined as “within ±2 min,” “within ±1 min” and “at the exact same time.”Results: The percentage of SMBG and FGM values in the clinically acceptable zone A + B in Clarke and consensus error grid analyses were 97.9 and 99.2%, respectively. Deming regression (x‐axis: FGM values, y‐axis: SMBG values) determined a slope of 0.9128 (95% confidence interval 0.9008–0.9247) and an intercept of +15.94 mg/dL (95% confidence interval 14.05–17.84). FGM values were lower than SMBG values in the lower glucose range, and higher in the higher glucose range. The shorter the time lag between measurements, the higher the rate of concordance between FGM and SMBG values.Conclusions: The results of this study provided evidence on the reliability of FGM in Japanese patients with type 1 diabetes in home conditions. Based on the results, if an abnormal glucose value is detected by FGM, SBMG should then be used to confirm the result.Keywords
This publication has 19 references indexed in Scilit:
- User Performance Evaluation of Four Blood Glucose Monitoring Systems Applying ISO 15197:2013 Accuracy Criteria and Calculation of Insulin Dosing ErrorsDiabetes Therapy, 2018
- Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic OutcomesDiabetes Technology & Therapeutics, 2017
- Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trialThe Lancet, 2016
- Intensive Diabetes Treatment and Cardiovascular Outcomes in Type 1 Diabetes: The DCCT/EDIC Study 30-Year Follow-upDiabetes Care, 2016
- Diagnostic criteria for slowly progressive insulin-dependent (type 1) diabetes mellitus (SPIDDM) (2012): report by the Committee on Slowly Progressive Insulin-Dependent (Type 1) Diabetes Mellitus of the Japan Diabetes SocietyDiabetology International, 2015
- Diagnostic criteria for acute‐onset type 1 diabetes mellitus (2012): Report of the Committee of Japan Diabetes Society on the Research of Fulminant and Acute‐onset Type 1 Diabetes MellitusJournal of Diabetes Investigation, 2013
- Report of the Committee of the Japan Diabetes Society on the Research of Fulminant and Acute‐onset Type 1 Diabetes Mellitus: New diagnostic criteria of fulminant type 1 diabetes mellitus (2012)Journal of Diabetes Investigation, 2012
- Limitations of Conventional Methods of Self-Monitoring of Blood GlucoseDiabetes Care, 2001
- A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose.Diabetes Care, 2000
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987