Simultaneous spatial and temporal regularization in low‐dose dynamic contrast‐enhanced CT cerebral perfusion studies
Authors:
Open Access
- 6 April 2023
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (6) , e13983
Abstract
Purpose: To apply total generalized variation (TGV) and its combination with low‐rank and sparse decomposition (LRSD) (LTGV) to cerebral perfusion studies using low‐dose dynamic contrast‐enhanced (DCE) CT and to quantitatively evaluate their performances through comparisons with those without any regularizers and those of total variation (TV) and its combination with LRSD (LTV) using simulation and clinical data.Methods: The simulation study used a realistic digital brain phantom. Low‐dose DCE‐CT images were reconstructed using the regularizers and primal‐dual algorithm. Subsequently, cerebral perfusion parameter (CPP) images were generated from them. Thereafter, their quality was evaluated based on the peak signal‐to‐noise ratio (PSNR) and structural similarity index measure (SSIM). Further, the accuracy of CPP estimation was evaluated through a linear regression analysis between the CPP values obtained by the above regularizers and those obtained from the noise‐free DCE‐CT images. In addition, the mean and standard deviation of the CPP were calculated (region analysis). In the clinical study, low‐dose DCE‐CT images were generated using normal‐dose images acquired from a patient, and CPP images were generated from them similar to that in the simulation study.Results: When using LTV and LTGV, both PSNR and SSIM were higher than those of the other methods with increasing regularization parameter values. The results of the linear regression and region analyses demonstrated that TGV generally exhibited the best performance, followed by LTGV, and finally that of TV was significantly different from those of the other regularizers. Despite an overall consistency between the simulation and clinical results, certain inconsistencies appeared owing to the difference in generating low‐dose DCE‐CT images.Conclusions: The results implied that TGV and LTGV were useful in improving the accuracy of CPP estimation using low‐dose DCE‐CT. This study provides an improved understanding of the performance of regularizers and is expected to aid in the selection of a suitable regularizer for low‐dose DCE‐CT perfusion studies.Keywords
This publication has 44 references indexed in Scilit:
- Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle–Pock algorithmPhysics in Medicine & Biology, 2012
- TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow mapsPhysics in Medicine & Biology, 2011
- Robust principal component analysis?Journal of the ACM, 2011
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studiesPhysics in Medicine & Biology, 2005
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Tracer arrival timing‐insensitive technique for estimating flow in MR perfusion‐weighted imaging using singular value decomposition with a block‐circulant deconvolution matrixMagnetic Resonance in Medicine, 2003
- Quantitative Evaluation of Mean Transit Times Obtained with Dynamic Susceptibility Contrast-Enhanced MR Imaging and with 133Xe SPECT in Occlusive Cerebrovascular DiseaseAmerican Journal of Roentgenology, 2002
- Nonlinear total variation based noise removal algorithmsPhysica D: Nonlinear Phenomena, 1992
- Measurement of tissue perfusion by dynamic computed tomographyBritish Journal of Radiology, 1991