Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation
Author:
- 10 April 2002
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 24 (5) , 337-347
Abstract
Progressive loosening of bone fixation screws is a well-documented phenomenon, induced by stress shielding and subsequent adaptive bone remodeling which results in bone loss around the screw. A set of two-dimensional computational (finite element) models was developed in order to test the effect of various engineering designs of fixation screws on the predicted screw-bone stress transfer, and consequently, on the biomechanical conditions for osteosynthesis. A dimensionless set of stress-transfer parameters (STP) was developed to quantify the screw-bone load sharing, enabling a convenient rating to be given of the biomechanical compatibility of practically any given screw design according to the nature of the simulated mechanical interaction. The results indicated that newly proposed screw designs, i.e. a "graded-stiffness" composite screw with a reduced-stiffness-titanium core and outer polymeric threads and an "active-compression" hollow screw which generates compressive stresses on the surrounding bone, are expected to provide significantly better biomechanical performances in terms of the STP criteria, compared with conservative screw designs. Accordingly, the present work demonstrates that finite element computer simulations can be used as a powerful tool for design and evaluation of bone screws, including geometrical features, material characteristics and even coatings.Keywords
This publication has 19 references indexed in Scilit:
- Spine UpdateSpine, 2000
- 2D-finite element analyses and histomorphology of lag screws with and without a biconcave washerJournal of Biomechanics, 1999
- The Significance of Hardware Failure in Anterior Cervical Plate FixationSpine, 1998
- Einflußfaktoren auf die Verankerungsstabilität von Wirbelsäulenknochenschrauben - Eine experimentelle StudieZeitschrift für Orthopädie und ihre Grenzgebiete, 1998
- Periprosthetic bone remodelling after cementless total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1997
- Cancellous Bone Screw Thread Design and Holding PowerJournal of Orthopaedic Trauma, 1996
- Factors Affecting the Pullout Strength of Cancellous Bone ScrewsJournal of Biomechanical Engineering, 1996
- Complications of Posterior Cervical PlatingSpine, 1995
- The mechanism of bone remodeling and resorption around press-fitted THA stemsJournal of Biomechanics, 1993
- Bone ingrowth and stress shielding with a porous surface coated fracture fixation plateJournal of Biomedical Materials Research, 1979