Magnetic resonance imaging of in vivo kinematics after total knee arthroplasty
Authors:
Open Access
- 21 January 2005
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (2) , 172-178
Abstract
Purpose: To improve the quality of magnetic resonance imaging (MRI) on knees after total knee arthroplasty (TKA) by minimizing image artifacts caused by metallic implants, and to establish a method determining in vivo kinematics of TKA knees using MRI.Materials and Methods: Two knee implants made of cobalt‐chrome and oxidized zirconium were tested with different pulse sequences and imaging parameters. Then, in vivo kinematic MRI was performed on five well‐functioning TKAs under simulated weight‐bearing conditions. Kinematic measurements were made and a linear correlation test was run between the tibio‐ and patellofemoral measurements.Results: The best images with minimum metallic artifacts were observed using oxidized zirconium implants, a fast spin echo sequence (FSE), thin slice thickness, and high readout gradient. TKA kinematics exhibited a large deviation from the normal kinematics and considerable patient‐to‐patient variability. However, significant linear correlations between tibiofemoral and patellofemoral kinematics were observed (R = −0.96, 0.92, 0.88).Conclusion: Metallic artifacts due to orthopedic implants can be reduced in MR images for some materials, appropriate pulse sequence, and imaging parameters selection, enabling MR quantification of knee kinematics. Tibiofemoral kinematics appears to affect patellofemoral position after total knee arthroplasty. J. Magn. Reson. Imaging 2005;21:172–178.Keywords
This publication has 21 references indexed in Scilit:
- A three‐dimensional MRI analysis of knee kinematicsJournal of Orthopaedic Research, 2004
- In Vivo Three-Dimensional Patellar Tracking on the FemurClinical Orthopaedics and Related Research, 2003
- Patellar position after total knee arthroplasty: Influence of femoral component malpositionThe Journal of Arthroplasty, 2003
- Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, cobalt‐alloy, and stainless steel stentsMagnetic Resonance in Medicine, 2003
- Magnetic Resonance Imaging of Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2003
- Technical Considerations: CT and MR Imaging in the Postoperative Orthopedic PatientSeminars in Musculoskeletal Radiology, 2002
- Improved MR imaging for patients with metallic implants☆Magnetic Resonance Imaging, 2000
- Functional Analysis of Pre and Post-Knee Surgery: Total Knee Arthroplasty and ACL ReconstructionJournal of Biomechanical Engineering, 1993
- Knee Motion in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1990
- Closed-form solution of absolute orientation using orthonormal matricesJournal of the Optical Society of America A, 1988