Mapping magnetization transfer saturation (MTsat) in human brain at 7T: Protocol optimization under specific absorption rate constraints
Open Access
- 30 June 2021
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2562-2576
Abstract
Purpose: To optimize a whole‐brain magnetization transfer saturation (MTsat) protocol at 7T, focusing on maximizing obtainable MTsat under the constraints of specific absorption rate (SAR) and transmit field inhomogeneity, while avoiding bias and keeping scan time short.Theory and Methods: MTsat is a semi‐quantitative metric, obtained by spoiled gradient‐echo MRI in the imaging steady‐state. Optimization was based on an established 7T dual flip angle protocol, and focused on MT pulse, readout flip angle, repetition time (TR), offset frequency (Δ), and correction of residual effects from transmit field inhomogeneities by separate flip angle mapping.Results: A 100% SAR level was reached at a 180° MT pulse flip angle, using a compact sinc main lobe (4 ms duration) and minimum TR = 26.5 ms. The use of Δ = +2.0 kHz caused no discernible direct saturation, while Δ = −2.0 kHz resulted in 45% higher MTsat in white matter (WM) compared to Δ = +2.0 kHz. A 4° readout flip angle eliminated bias while yielding a good signal‐to‐noise ratio. Increased TR yielded only a little increase in MTsat, and TR = 26.5 ms (scan time 04:58 min) was thus selected. Post hoc transmit field correction clearly improved homogeneity, especially in WM.Conclusions: The range of MTsat is limited at 7T, and this can partly be overcome by the exploitation of the asymmetry of the macromolecular lineshape through the sign of Δ. To reduce scan time, a compact MT pulse with a sufficiently narrow frequency response should be used. TR and readout flip angle should be kept short/small. Transmit field correction through separate flip angle mapping is required.Keywords
Funding Information
- Vetenskapsrådet (MH 2017‐00995, NT 2014‐6193)
This publication has 52 references indexed in Scilit:
- MRI investigation of the sensorimotor cortex and the corticospinal tract after acute spinal cord injury: a prospective longitudinal studyThe Lancet Neurology, 2013
- Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validationFrontiers in Neuroscience, 2013
- Quantitative magnetization transfer imaging of human brain at 7 TNeuroImage, 2013
- Contrast at high field: Relaxation times, magnetization transfer and phase in the rat brain at 16.4 TMagnetic Resonance in Medicine, 2011
- Regional specificity of MRI contrast parameter changes in normal ageing revealed by voxel-based quantification (VBQ)NeuroImage, 2011
- Identification of signal bias in the variable flip angle method by linear display of the algebraic ernst equationMagnetic Resonance in Medicine, 2011
- Bound pool fractions complement diffusion measures to describe white matter micro and macrostructureNeuroImage, 2011
- Magnetization transfer phenomenon in the human brain at 7 TNeuroImage, 2010
- Improved segmentation of deep brain grey matter structures using magnetization transfer (MT) parameter mapsNeuroImage, 2009
- Simultaneous measurement of saturation and relaxation in human brain by repetitive magnetization transfer pulsesNMR in Biomedicine, 2005