Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography
- 1 June 2015
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (6) , 659-665
Abstract
Background: Despite the well-established requirement for radiation dose reduction there are few studies examining the potential for lower extremity CT angiography (CTA) at 70 kVp. Purpose: To compare the image quality and radiation dose of lower extremity CTA at 70 kVp using a dual-source CT system with an integrated circuit detector to similar studies at 120 kVp. Material and Methods: A total of 62 patients underwent lower extremity CTA. Thirty-one patients were examined at 70 kVp using a second generation dual-source CT with an integrated circuit detector (70 kVp group) and 31 patients were evaluated at 120 kVp using a first generation dual-source CT (120 kVp group). The attenuation and image noise were measured and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists assessed image quality. Radiation dose was compared. Results: The mean attenuation of the 70 kVp group was higher than the 120 kVp group (575 ± 149 Hounsfield units [HU] vs. 258 ± 38 HU, respectively, P < 0.001) as was SNR (44.0 ± 22.0 vs 32.7 ± 13.3, respectively, P = 0.017), CNR (39.7 ± 20.6 vs 26.6 ± 11.7, respectively, P = 0.003) and the mean image quality score (3.7 ± 0.1 vs. 3.2 ± 0.3, respectively, P < 0.001). The inter-observer agreement was good for the 70 kVp group and moderate for the 120 kVp group. The dose-length product was lower in the 70 kVp group (264.5 ± 63.1 mGy × cm vs. 412.4 ± 81.5 mGy × cm, P < 0.001). Conclusion: Lower extremity CTA at 70 kVp allows for lower radiation dose with higher SNR, CNR, and image quality when compared with standard 120 kVp.Keywords
This publication has 23 references indexed in Scilit:
- Diagnostic Efficiency of Low-Dose CT Angiography Compared With Conventional Angiography in Peripheral Arterial OcclusionsAmerican Journal of Roentgenology, 2013
- Assessment of Vascular Contrast and Depiction of Stenoses in Abdominopelvic and Lower Extremity VasculatureAcademic Radiology, 2012
- Low-Dose Multidetector CT Angiography in the Evaluation of Infrarenal Aorta and Peripheral Arterial Occlusive DiseaseRadiology, 2012
- The Value of Dual-Energy Bone Removal in Maximum Intensity Projections of Lower Extremity Computed Tomography AngiographyInvestigative Radiology, 2009
- Comparison of CT and Catheter Arteriography for Evaluation of Peripheral Arterial DiseaseVascular and Endovascular Surgery, 2005
- Aortoiliac and Lower Extremity Arteries Assessed with 16–Detector Row CT Angiography: Prospective Comparison with Digital Subtraction AngiographyRadiology, 2005
- Low-dose multidetector-row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSAEuropean Radiology, 2005
- Multidetector row CT angiography of the abdominal aorta and lower extremities in patients with peripheral arterial occlusive disease: diagnostic accuracy and interobserver agreementEuropean Journal of Radiology, 2004
- Infrarenal Aortic and Lower-Extremity Arterial Disease: Diagnostic Performance of Multi–Detector Row CT AngiographyRadiology, 2004
- Multidetector CT Angiography of the Aortoiliac System and Lower Extremities: A Prospective Comparison with Digital Subtraction AngiographyAmerican Journal of Roentgenology, 2003