Clinical utility of three‐dimensional echocardiography in the evaluation of tricuspid regurgitation induced by implantable device leads
Authors:
- 19 August 2016
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 33 (11) , 1689-1696
Abstract
Objectives: Implantable device leads could cause tricuspid regurgitation (TR) by interfering with leaflet motion. This study evaluated the feasibility of using three‐dimensional transthoracic echocardiography (3DTTE) to identify lead‐induced tricuspid regurgitation (LITR).Methods: 3DTTE full‐volume images of the right ventricle (RV) and zoomed images of the tricuspid valve were obtained in 207 patients with implanted devices, and the images were analyzed. TR severity was estimated based on measurements of the proximal isovelocity surface area (PISA) radius.Results: 3DTTE clearly identified the course and position of the leads in 74% of the patients. The lead tips were located in the RV apex or outflow tract in 95% of patients and in the interventricular septum (IVS) in 5% of patients. At the tricuspid annular level, 25% of leads were impinging on a leaflet, 41% were located in the commissure of two leaflets, and 34% were in the middle of the tricuspid orifice. 3D images revealed that when the lead tip was in the IVS or the lead was impinging on a leaflet, the device lead was more likely to interfere with leaflet mobility (P<.05). Interfering leads were associated with more significant TR than noninterfering leads (P<.05).Conclusions: 3DTTE showed a clear association between lead interference and TR worsening after lead placement. 3DTTE guidance should be considered for the placement of leads.Keywords
Funding Information
- National Health and Family Planning Commission of the People's Republic of China (2015ZDA013)
This publication has 22 references indexed in Scilit:
- Tricuspid Regurgitation Following Implantation of a Pacemaker/Cardioverter-DefibrillatorCurrent Cardiology Reports, 2013
- Prevalence and Mechanism of Tricuspid Regurgitation following Implantation of Endocardial Leads for Pacemaker or Cardioverter-DefibrillatorJournal of the American Society of Echocardiography, 2012
- EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional EchocardiographyJournal of the American Society of Echocardiography, 2012
- European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease)European Heart Journal - Cardiovascular Imaging, 2010
- Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodesEP Europace, 2009
- The Tricuspid ValveCirculation, 2009
- Tricuspid Valve Malfunction and Ventricular Pacemaker Lead: Case Report and Review of the LiteratureEchocardiography, 2006
- Severe Symptomatic Tricuspid Valve Regurgitation Due to Permanent Pacemaker or Implantable Cardioverter-Defibrillator LeadsJACC, 2005
- Impact of tricuspid regurgitation on long-term survivalJACC, 2004
- Autopsy Findings with Permanent Pervenous PacemakersCirculation, 1969