Design, Fabrication, and Validation of a Petri Dish-Compatible PDMS Bioreactor for the Tensile Stimulation and Characterization of Microtissues
Open Access
- 26 September 2020
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 11 (10) , 892
Abstract
In this paper, we report on a novel biocompatible micromechanical bioreactor (actuator and sensor) designed for the in situ manipulation and characterization of live microtissues. The purpose of this study was to develop and validate an application-targeted sterile bioreactor that is accessible, inexpensive, adjustable, and easily fabricated. Our method relies on a simple polydimethylsiloxane (PDMS) molding technique for fabrication and is compatible with commonly-used laboratory equipment and materials. Our unique design includes a flexible thin membrane that allows for the transfer of an external actuation into the PDMS beam-based actuator and sensor placed inside a conventional 35 mm cell culture Petri dish. Through computational analysis followed by experimental testing, we demonstrated its functionality, accuracy, sensitivity, and tunable operating range. Through time-course testing, the actuator delivered strains of over 20% to biodegradable electrospun poly (D, L-lactide-co-glycolide) (PLGA) 85:15 non-aligned nanofibers (~91 µm thick). At the same time, the sensor was able to characterize time-course changes in Young’s modulus (down to 10–150 kPa), induced by an application of isopropyl alcohol (IPA). Furthermore, the actuator delivered strains of up to 4% to PDMS monolayers (~30 µm thick), simultaneously characterizing their elastic modulus up to ~2.2 MPa. The platform repeatedly applied dynamic (0.23 Hz) tensile stimuli to live Human Dermal Fibroblast (HDF) cells for 12 hours (h) and recorded the cellular reorientation towards two angle regimes, with averages of −58.85° and +56.02°. The device biocompatibility with live cells was demonstrated for one week, with no signs of cytotoxicity. We can conclude that our PDMS bioreactor is advantageous for low-cost tissue/cell culture micromanipulation studies involving mechanical actuation and characterization. Our device eliminates the need for an expensive experimental setup for cell micromanipulation, increasing the ease of live-cell manipulation studies by providing an affordable way of conducting high-throughput experiments without the need to open the Petri dish, reducing manual handling, cross-contamination, supplies, and costs. The device design, material, and methods allow the user to define the operational range based on their targeted samples/application.Keywords
Funding Information
- National Science Foundation (1809047)
This publication has 52 references indexed in Scilit:
- Cell Stiffness Is a Biomarker of the Metastatic Potential of Ovarian Cancer CellsPLOS ONE, 2012
- Poly(lactide- co -glycolide) porous scaffolds for tissue engineering and regenerative medicineInterface Focus, 2012
- Measurement of nonlinear mechanical properties of PDMS elastomerMicroelectronic Engineering, 2011
- Bioreactor System Using Noninvasive Imaging and Mechanical Stretch for Biomaterial ScreeningAnnals of Biomedical Engineering, 2011
- Bioreactor-based roadmap for the translation of tissue engineering strategies into clinical productsTrends in Biotechnology, 2009
- Effects of strain rate, mixing ratio, and stress–strain definition on the mechanical behavior of the polydimethylsiloxane (PDMS) material as related to its biological applicationsBiomedical Microdevices, 2008
- Stability of Adhesion Clusters and Cell Reorientation under Lateral Cyclic TensionBiophysical Journal, 2008
- Two Characteristic Regimes in Frequency-Dependent Dynamic Reorientation of Fibroblasts on Cyclically Stretched SubstratesBiophysical Journal, 2008
- Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motilityMicroelectronic Engineering, 2008
- Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/NanosystemsBiomedical Microdevices, 2005