Temperature-controlled autocollimator with ultrahigh angular measuring precision
Authors:
- 1 December 2005
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 76 (12) , 125106
Abstract
A temperature-controlled autocollimator with ultrahigh angular measuring precision is proposed in this article, which is different from our previous publication [J. Yuan and X. W. Long, Rev. Sci. Instrum. 74, 1362 (2003)]. The autocollimator consists of a zoom lens illuminating a charge-coupled device (CCD). This design provides a compact size and increased stability without compromising precision. Moreover, this design makes it possible to detect a target mirror with either plane reflectors or spherical reflectors. Devices for shock absorption and heat insulation were implemented to diminish external interferences. A special temperature-control system for the autocollimator is designed to control the temperature of the autocollimator. The temperature of the autocollimator fluctuates less than . The CCD camera’s noise is a fatal obstacle that prevents us from achieving an ultrahigh angular measuring precision. In this article, the influence of the CCD camera’s noise on the measuring resolution is analyzed theoretically in detail. Based on the analysis, some special noise-suppressing methods to eliminate the influence of the CCD camera’s noise are proposed. Both the influence of the CCD camera’s noise and the noise-suppressing methods have not been discussed in our previous publication [J. Yuan and X. W. Long, Rev. Sci. Instrum. 74, 1362 (2003)]. By using the methods mentioned above, the measuring precision of the autocollimator has been greatly improved and the requirements on the external condition have been greatly reduced. The method is proved to be reliable by a prototype experiment. Two-axis angular displacement can be measured simultaneously and a measuring precision of has been achieved, which is currently the highest measuring precision in the world.
Keywords
This publication has 21 references indexed in Scilit:
- Angle measurement based on the internal-reflection effect and the use of right-angle prismsApplied Optics, 1995
- Autocollimator for spectroscopy of broad resonances with pulsed lasersApplied Optics, 1995
- Improving the linearity of the Michelson interferometric angular measurement by a parameter compensation methodApplied Optics, 1993
- Angle measurement based on the internal-reflection effect: a new methodApplied Optics, 1992
- New optical method for measuring small-angle rotationsApplied Optics, 1988
- Autocollimator based on moire deflectometryApplied Optics, 1984
- High-precision, wide-range, dual-axis, angle monitoring systemReview of Scientific Instruments, 1983
- High accuracy profile measurement of quasi-conical mirror surfaces by laser autocollimationPrecision Engineering, 1982
- Active annular-beam laser autocollimator systemApplied Optics, 1975
- An Interferometer for Precision Angle MeasurementsApplied Optics, 1963