Comparison of complementary metal oxide semiconductor and charge-coupled device intraoral X-ray detectors using subjective image quality
Authors:
- Jp ScheetzJSJp Scheetz
- Ag FarmanAFAg Farman
- 1 November 2003
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 32 (6) , 408-411
Abstract
To compare the subjective image quality of the newer generation Schick CDR detector employing complementary metal oxide semiconductor (CMOS) technology with images using the earlier generation charge-coupled device (CCD) Schick CDR detector. All radiographic images were made using the same formalin-fixed adult cadaver maxilla with surrounding natural soft tissues in place. The X-ray generator used was a Villa Sistemi Medicali Diamatic srl AP/Explor X operated at 70 kVp and 8 mA. The source-to-detector distance was set at 38 cm and an optical bench was used to ensure reproducible beam geometry. A range of exposures was applied for both detectors. A panel of nine dentists independently observed and evaluated images made at each exposure. For both detectors, the three images ranked highest were randomized for re-evaluation in panels of six images. Each image was repeated randomly a total of 10 times. Features chosen as observation points were: (1) proximal dental caries; (2) gingival soft tissues; (3) cortical bone; (4) root canal space; (5) root apices; (6) periodontal ligament space; and (7) endodontic instrument tip clarity. Comparisons were made by use of odds ratio analysis applying a 95% confidence level. Interrater and intrarater reliabilities were computed to assess consistency in observer ratings. The CMOS sensor was rated as outperforming its CCD predecessor for depiction of cortical bone and root apices; the CCD detector was only rated superior for depiction of root canal space. No significant difference was found between the two detectors in perceived depiction of proximal dental caries, gingival soft tissues, periodontal ligament space or endodontic instruments. Combining rating scores from each of the tasks, CMOS and CCD detectors had a similar proportion of image ratings of excellent, acceptable and poor. Regarding subjective image quality, the Schick CMOS and CCD detectors were perceived to produce radiographic images of similar overall quality.Keywords
This publication has 14 references indexed in Scilit:
- Fundamentals of image acquisition and processing in the digital eraOrthodontics & Craniofacial Research, 2003
- Comparison of three intra-oral storage phosphor systems using subjective image qualityDentomaxillofacial Radiology, 2000
- Radiographic detection of approximal caries: a comparison of dental films and digital imaging systemsDentomaxillofacial Radiology, 2000
- Observer differentiation of proximal enamel mechanical defects versus natural proximal dental caries with computed dental radiographyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1996
- Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems: an in vitro study.Dentomaxillofacial Radiology, 1995
- Flash Dent: an alternative charge-coupled device/scintillator-based direct digital intraoral radiographic system.Dentomaxillofacial Radiology, 1994
- Direct digital dental x-ray imaging with Visualix/VIXAOral Surgery, Oral Medicine, Oral Pathology, 1993
- Sens-A-RayOral Surgery, Oral Medicine, Oral Pathology, 1992
- Direct digital radiography for the detection of periodontal bone lesionsOral Surgery, Oral Medicine, Oral Pathology, 1992
- Presentation and physical evaluation of RadioVisioGraphyOral Surgery, Oral Medicine, Oral Pathology, 1989