A comparison of 60 Hz uniform magnetic and electric induction in the human body
Authors:
- 1 December 1997
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 42 (12) , 2319-2329
Abstract
High-resolution computations of induced fields are used to assess equivalent source levels for human exposure to uniform low-frequency electric and magnetic fields. These results pertain to 60 Hz foot-to-head electric excitation of the body in three positions with respect to a ground plane, and to magnetic excitation by three orthogonal source orientations. All computations are based on an anatomically derived human body model composed of 1736 873 cubic voxels with 3.6 mm edges. The data for magnetic excitation are computed using a scalar potential finite difference (SPFD) method, while those for electric excitation are computed using a hybrid method based on the SPFD method coupled with a quasistatic finite difference time domain code. The data are analysed in two ways, using an induced current density threshold of . Firstly, the various field strengths required to produce a whole-body average current density magnitude equal to the threshold are derived for each configuration, and the associated current density levels in various organs and tissues are presented. It is found that the average current density magnitude values in at least one tissue group can be up to 3 (5) times greater than the whole-body average under electric (magnetic) excitation, and that the associated maximum values can be up to 46 (28) times greater than the whole-body average under electric (magnetic) excitation, for at least one source/body configuration. Secondly, the data are analysed from the opposite point of view, in which the source levels required to induce average or maximum induced current density magnitudes at the threshold level in specific tissue groups are determined. Evaluations such as the present one should prove useful in the development of protection standards, and are also expected to aid in the understanding of results from various animal and tissue culture studies.Keywords
This publication has 20 references indexed in Scilit:
- Influence of human model resolution on computed currents induced in organs by 60‐Hz magnetic fieldsBioelectromagnetics, 1997
- Comparison of coupling of humans to electric and magnetic fields with frequencies between 100 Hz and 100 kHzBioelectromagnetics, 1997
- Exposure to 50-Hz Electric Field and Incidence of Leukemia, Brain Tumors, and Other Cancers among French Electric Utility WorkersAmerican Journal of Epidemiology, 1996
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- Electric fields induced in rat and human models by 60‐Hz magnetic fields: Comparison of calculated and measured valuesBioelectromagnetics, 1992
- Finite difference calculations of current densities in a homogeneous model of a man exposed to extremely low frequency electric fieldsBioelectromagnetics, 1987
- Current densities measured in human models exposed to 60‐Hz electric fieldsBioelectromagnetics, 1985
- Numerical calculation and measurement of 60-Hz current densities induced in an upright grounded cylinderBioelectromagnetics, 1985
- Application of Finite Element Method to Analysis of Induced Current Desities Inside Human Model Exposed to 60-Hz Electric FieldIEEE Transactions on Power Apparatus and Systems, 1984
- The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologistMedical & Biological Engineering & Computing, 1967