Usefulness of semi-automatic volumetry compared to established linear measurements in predicting lymph node metastases in MSCT
Authors:
- 1 June 2011
- journal article
- Published by SAGE Publications in Acta Radiologica
- Vol. 52 (5) , 540-546
Abstract
Background Volumetry of lymph nodes potentially better reflect asymmetric size alterations independently of lymph node orientation in comparison to metric parameters (e.g. long-axis diameter). Purpose To distinguish between benign and malignant lymph nodes by comparing 2D and semi-automatic 3D measurements in MSCT. Material and Methods FDG-18 PET-CT was performed in 33 patients prior to therapy for malignant melanoma at stage III/IV. One hundred and eighty-six cervico-axillary, abdominal and inguinal lymph nodes were evaluated independently by two radiologists, both manually and with the use of semi-automatic segmentation software. Long axis (LAD), short axis (SAD), maximal 3D diameter, volume and elongation were obtained. PET-CT, PET-CT follow-up and/or histology served as a combined reference standard. Statistics encompassed intra-class correlation coefficients and ROC curves. Results Compared to manual assessment, semi-automatic inter-observer variability was found to be lower, e.g. at 2.4% (95% CI 0.05–4.8) for LAD. The standard of reference revealed metastases in 90 (48%) of 186 lymph nodes. Semi-automatic prediction of lymph node metastases revealed highest areas under the ROC curves for volume (reader 1 0.77, 95%CI 0.64–0.90; reader 2 0.76, 95%CI 0.59–0.86) and SAD (reader 1 0.76, 95%CI 0.64–0.88; reader 2 0.75, 95%CI 0.62–0.89). The findings for LAD (reader 1 0.73, 95%CI 0.60–0.86; reader 2 0.71, 95%CI 0.71, 95%CI 0.57–0.85) and maximal 3D diameter (reader 1 0.70, 95%CI 0.53-0.86; reader 2 0.76, 95%CI 0.50–0.80) were found substantially lower and for elongation (reader 1 0.65, 95%CI 0.50–0.79; reader 2 0.66, 95%CI 0.52–0.81) significantly lower (p < 0.05). Conclusion Semi-automatic analysis of lymph nodes in malignant melanoma is supported by high segmentation quality and reproducibility. As compared to established SAD, semi-automatic lymph node volumetry does not have an additive role for categorizing lymph nodes as normal or metastatic in malignant melanoma.Keywords
This publication has 31 references indexed in Scilit:
- New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)European Journal of Cancer, 2009
- Evaluation of lymph nodes with RECIST 1.1European Journal of Cancer, 2009
- Automated measurement of lymph nodes: a phantom studyEuropean Radiology, 2008
- Role of PET in the Initial Staging of Cutaneous Malignant Melanoma: Systematic ReviewRadiology, 2008
- Semi-automated volumetric analysis of lymph node metastases in patients with malignant melanoma stage III/IV-A feasibility studyEuropean Radiology, 2008
- High-Risk Melanoma: Accuracy of FDG PET/CT with Added CT Morphologic Information for Detection of MetastasesRadiology, 2007
- Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibilityEuropean Radiology, 2003
- Interobserver and Intraobserver Variability in Measurement of Non–Small-Cell Carcinoma Lung Lesions: Implications for Assessment of Tumor ResponseJournal of Clinical Oncology, 2003
- Positron emission tomography is superior to computed tomography for metastatic detection in melanoma patientsAnnals of Surgical Oncology, 2002
- Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)European Radiology, 2002