Cardiac resynchronization therapy outcomes in patients with chronic heart failure
Authors:
- Michael DrozdMDMichael Drozd
- John GierulaJGJohn Gierula
- Judith E. LowryJLJudith E. Lowry
- Maria F. PatonMPMaria F. Paton
- Eleanor JoyEJEleanor Joy
- Haqeel A. JamilHJHaqeel A. Jamil
- Richard M. CubbonRCRichard M. Cubbon
- Mark T. KearneyMKMark T. Kearney
- David A. CairnsDCDavid A. Cairns
- Klaus K. WitteKWKlaus K. Witte
- 1 December 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 18 (12) , 962-967
Abstract
Cardiac resynchronization therapy (CRT) for chronic heart failure with left ventricular systolic dysfunction (LVSD) consistently improves survival against optimal medical therapy alone. Limited data exist comparing the outcomes between CRT with pacemaker (CRT-P) and with defibrillator (CRT-D). We aimed to investigate the long-term prognosis of patients who received CRT-P or CRT-D. Data were prospectively collected from consecutive patients with standard indications for CRT, who were implanted at a single large tertiary centre between 2008 and 2012. All-cause mortality was compared between those patients who received either CRT-P or CRT-D. A subgroup analysis was performed in patients with ischaemic cardiomyopathy. During the period in question, 795 patients received CRT devices: 544 (68.4%) CRT-P and 251 (31.6%) CRT-D. The mean follow-up was 1072 ± (SD 556) days. Overall, there was no survival benefit in those patients implanted with a CRT-D compared with CRT-P (hazard ratio 1.09, 95% confidence interval 0.84–1.41, P = 0.51). In patients with ischaemic chronic heart failure [n = 530 (66.7%)], there was a trend for improved survival with CRT-D; however, this was not significant after adjustment. In a subgroup analysis, there were no differences in mode-specific mortality in those patients implanted with CRT-D compared with CRT-P. In this large consecutive patient cohort, we did not find a survival benefit of CRT-D compared with CRT-P. Patients indicated for CRT devices may not reliably benefit from the addition of a defibrillator.Keywords
This publication has 33 references indexed in Scilit:
- Changing Characteristics and Mode of Death Associated With Chronic Heart Failure Caused by Left Ventricular Systolic DysfunctionCirculation: Heart Failure, 2011
- Reverse Remodeling and the Risk of Ventricular Tachyarrhythmias in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy)JACC, 2011
- Are complications of implantable defibrillators under-estimated and benefits over-estimated?EP Europace, 2009
- ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesCirculation, 2008
- Effects of Cardiac Resynchronization Therapy With or Without a Defibrillator on Survival and Hospitalizations in Patients With New York Heart Association Class IV Heart FailureCirculation, 2007
- The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillatorEuropean Heart Journal, 2006
- Sustained Reverse Left Ventricular Structural Remodeling With Cardiac Resynchronization at One Year Is a Function of EtiologyCirculation, 2006
- Cost Effectiveness of Cardiac Resynchronization Therapy in the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) TrialJACC, 2005
- Mode of Death in Advanced Heart FailureJACC, 2005
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002