Influence of Wall Compliance on Hemodynamics in Models of Abdominal Aortic Aneurysm
- 1 August 2007
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 14 (4) , 593-599
Abstract
Purpose: To determine complementary criteria to existing morphological criteria, which are not reliable but are used to justify surgical intervention to treat abdominal aortic aneurysm (AAA). Methods: An experimental study was conducted in which 2 models of AAA, 1 rigid and 1 soft, were used to study the influence of compliance on aneurysm dynamics. The heart rate was 70 beats per minute, and the mean flow rate was 1.02 L/min. Velocity measurements were made with particle image velocimetry in 2 planes parallel to flow (1 vertical and 1 horizontal). Results: The general flow patterns generated in the rigid AAA model were in agreement with the literature. In both models, a vortex occurred at the beginning of systolic deceleration in the proximal part of the AAA, near the anterior wall. The vortex remained confined to the proximal part during the entire cycle in the rigid model, whereas in the soft model, the vortex migrated to the distal segment during the cycle and impacted the AAA walls. This impact generated a local pressure increase on the wall. In the soft model, another vortex was created near the posterior wall. These vortices eroded and weakened the walls of the distal segment, which can cause rupture. Conclusion: Compliance of the aneurysm wall might become another criterion to justify surgical intervention.Keywords
This publication has 12 references indexed in Scilit:
- Compliance of abdominal aortic aneurysms: Evaluation of tissue Doppler imagingUltrasound in Medicine & Biology, 2004
- Hemodynamic Changes Occurring during the Progressive Enlargement of Abdominal Aortic AneurysmsAnnals of Vascular Surgery, 2004
- The Effect of Asymmetry in Abdominal Aortic Aneurysms Under Physiologically Realistic Pulsatile Flow ConditionsJournal of Biomechanical Engineering, 2003
- Steady and pulsatile flow studies in Abdominal Aortic Aneurysm models using Particle Image VelocimetryInternational Journal of Heat and Fluid Flow, 2000
- Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditionsJournal of Biomechanics, 1999
- On the abdominal aortic aneurysms: pulsatile state considerationsMedical Engineering & Physics, 1997
- On the identification of a vortexJournal of Fluid Mechanics, 1995
- Three-Dimensional Simulation of Blood Flow in an Abdominal Aortic Aneurysm—Steady and Unsteady Flow CasesJournal of Biomechanical Engineering, 1994
- Steady Flow in Abdominal Aortic Aneurysm ModelsJournal of Biomechanical Engineering, 1993
- Particle-Imaging Techniques for Experimental Fluid MechanicsAnnual Review of Fluid Mechanics, 1991