Abstract
An ACM (Atmospheric Corrosion Monitor) type corrosion sensor, consisting of a Fe-Ag galvanic couple was developed and applied for the evaluation of corrosivity of atmospheric environments. The sensor was designed considering mass-production and good reproducibility of results, making it convenient for long-term corrosion data acquisition. Besides the sensor output, I, temperature, relative humidity (RH) were also recorded by a microcomputer. By analyzing the magnitude and time variation of I, the occurrence and duration of rain, dew and dry periods, Train, Tdew and Tdry, respectively, could be distinguished and determined. And by referencing to the empirical I-RH calibrating curve, the amount of deposited sea salt, Ws, could also be estimated. It was also found that the corrosion loss could be estimated in both indoor and outdoor sites by analyzing sensor output. Corrosivities of some kinds of exposure sites, not only outdoor environments but also indoor environments, were evaluated by using the ACM sensor.Keywords
This publication has 3 references indexed in Scilit:
- ACM (Atmospheric Corrosion Monitor) Type Corrosion Sensor to Evaluate Corrosivity of Marine AtmosphereCorrosion Engineering, 1994
- Atmospheric Corrosion MonitoringCORROSION ENGINEERING, 1981
- Electrochemical monitoring of atmospheric corrosion phenomenaCorrosion Science, 1976