Optimizing Device Selection in Percutaneous Paravalvular Leak Closure: A Comparative Study of Different Transthoracic and Transesophageal Echocardiographic Techniques
- 20 February 2025
- journal article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 105 (6) , 1304-1310
Abstract
Background: Clinically significant paravalvular leak (PVL) may complicate both surgical and transcatheter valve implantation. Percutaneous PVL closure (PPVLC) is becoming an increasingly attractive alternative to redo surgery, with demonstrated lower mortality and morbidity rates. Echocardiographic techniques are crucial for accurate diagnosis, defect sizing, and determining the appropriate size of the sealing devices.Aims: There is no consensus on the optimal imaging modality for PVLs. We aimed to compare transthoracic and transesophageal echocardiographic measurements to accurately determine defect size and estimate device size.Methods: We reviewed hospital records to identify patients diagnosed with moderate to severe and severe PVL from 2018 to 2024. A total of 81 patients who underwent PPVLC were evaluated. Eight of these patients were excluded due to unsuccessful PPVLC, leaving 73 patients who were successfully treated. The defect size for all patients was evaluated using 2D transthoracic echocardiography (TTE), 2D transesophageal echocardiography (TEE), direct 3D TEE cropped volume rendering vena contracta (VC) measurement, and 3D TEE multiplanar reconstruction (3D TEE MPR).Results: Among the 73 patients, 42 underwent aortic PPVLC and 31 underwent mitral PPVLC. Proportional odds logistic regression analysis identified 3D TEE MPR measurement as the strongest predictor of device size accuracy, both overall and within the aortic/mitral subgroups. In the mitral subgroup, the predictive power of direct 3D TEE cropped volume rendering VC measurement and 3D TEE MPR measurement were similar. Furthermore, a cut‐off value of 7 mm was identified for hemodynamically significant jets as measured by 3D methods.Conclusion: Our findings suggest that using 3D TEE MPR significantly improves the accuracy of device size selection in both mitral and aortic PVL. Additionally, direct 3D TEE cropped volume rendering VC measurement can serve as a viable alternative for patients with mitral PVL.Keywords
This publication has 11 references indexed in Scilit:
- Guidelines for the Evaluation of Prosthetic Valve Function With Cardiovascular Imaging: A Report From the American Society of Echocardiography Developed in Collaboration With the Society for Cardiovascular Magnetic Resonance and the Society of Cardiovascular Computed TomographyJournal of the American Society of Echocardiography, 2024
- Percutaneous management of paravalvular leaksNature Reviews Cardiology, 2019
- Successful Percutaneous Mitral Paravalvular Leak Closure Is Associated With Improved Midterm SurvivalCirculation: Cardiovascular Interventions, 2017
- EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart diseaseEuropean Heart Journal, 2011
- Assessment of Percutaneous Catheter Treatment of Paravalvular Prosthetic RegurgitationJACC: Cardiovascular Imaging, 2010
- Use of Real Time Three-Dimensional Transesophageal Echocardiography in Intracardiac Catheter Based InterventionsJournal of the American Society of Echocardiography, 2009
- Percutaneous Transcatheter Closure of Prosthetic Mitral Paravalvular LeaksJACC: Cardiovascular Interventions, 2009
- Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiographyHeart, 2003
- Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trialJACC, 2000
- Reoperation for bioprosthetic valve dysfunction *1A decade of clinical experienceEuropean Journal of Cardio-Thoracic Surgery, 1991