Temporal changes of coronary artery plaque located behind the struts of the everolimus eluting bioresorbable vascular scaffold
- 13 October 2010
- journal article
- clinical trial
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 27 (6) , 859-866
Abstract
Implantation of a coronary stent results in a mechanical enlargement of the coronary lumen with stretching of the surrounding atherosclerotic plaque. Using intravascular ultrasound virtual-histology (IVUS-VH) we examined the temporal changes in composition of the plaque behind the struts (PBS) following the implantation of the everolimus eluting bioresorbable vascular scaffold (BVS). Using IVUS-VH and dedicated software, the composition of plaque was analyzed in all patients from the ABSORB B trial who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA) post-treatment and at 6-month follow-up. This dedicated software enabled analysis of the PBS after subtraction of the VH signal generated by the struts. The presence of necrotic core (NC) in contact with the lumen was also evaluated at baseline and follow-up. IVUS-VH data, recorded with s5i system, were available at baseline and 6-month follow-up in 15 patients and demonstrated an increase in both the area of PBS (2.45 ± 1.93 mm2 vs. 3.19 ± 2.48 mm2, P = 0.005) and the external elastic membrane area (13.76 ± 4.07 mm2 vs. 14.76 ± 4.56 mm2, P = 0.006). Compared to baseline there was a significant progression in the NC (0.85 ± 0.70 mm2 vs. 1.21 ± 0.92 mm2, P = 0.010) and fibrous tissue area (0.88 ± 0.79 mm2 vs. 1.15 ± 1.05 mm2, P = 0.027) of the PBS. The NC in contact with the lumen in the treated segment did not increase with follow-up (7.33 vs. 6.36%, P = 0.2). Serial IVUS-VH analysis of BVS-treated lesions at 6-month demonstrated a progression in the NC and fibrous tissue content of PBS.Keywords
This publication has 25 references indexed in Scilit:
- Intracoronary Optical Coherence Tomography and Histology at 1 Month and 2, 3, and 4 Years After Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffolds in a Porcine Coronary Artery ModelCirculation, 2010
- A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methodsThe Lancet, 2009
- Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis A substudy of the ABSORB clinical trialEuroIntervention, 2009
- Vascular Responses to Drug Eluting StentsArteriosclerosis, Thrombosis, and Vascular Biology, 2007
- Selective Clearance of Macrophages in Atherosclerotic Plaques by AutophagyJACC, 2007
- Pathology of Drug-Eluting Stents in HumansJACC, 2006
- Evaluation of Four-Year Coronary Artery Response After Sirolimus-Eluting Stent Implantation Using Serial Quantitative Intravascular Ultrasound and Computer-Assisted Grayscale Value Analysis for Plaque Composition in Event-Free PatientsJACC, 2005
- Mechanism of Late In-Stent Restenosis After Implantation of a Paclitaxel Derivate–Eluting Polymer Stent System in HumansCirculation, 2002
- Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data AnalysisCirculation, 2002
- Twenty-eight-day efficacy and phamacokinetics of the sirolimus-eluting stentCoronary Artery Disease, 2002