Sensing efficiency of three-dimensional textile sensors with an open-and-close structure for respiration rate detection
Authors:
- 30 March 2020
- journal article
- research article
- Published by SAGE Publications in Textile Research Journal
- Vol. 90 (19-20) , 2258-2274
Abstract
The strain-gauge type textile sensors adopted in many studies on respiration-sensing wearable systems have been reported to have two major limitations that result in reduced sensing accuracy and insufficient durability of the sensor. The two limitations are the inability to accurately monitor the changes in the three-dimensional (3D) body contour during changes in the respiration cycle and the frequent occurrence of baseline drifts. To solve these issues, this study proposes new types of textile respiration rate sensors with a 3D structure, which measure the respiration rate based on the variation in the size of the contacting section’s surface during respiration, rather than the changes in the length of the sensor, as in existing strain-gauge type sensors. Firstly, the sensing signals were analyzed based on morphology and size measurements. Then, the sensing reliability of three respiration rate sensor types, namely the no-filler, 3D hard, and 3D soft types, was analyzed by comparing their measurements with those of the SS5LB. Finally, the reproducibility and baseline drifts of the sensors’ measurements were evaluated by taking and comparing repeated measurements. As a result, the consistency of the sensing signals of the SS5LB and those of the two types of 3D sensors was higher than those of the no-filler type sensor, and the 3D soft type sensor had the highest reliability and reproducibility among the three new types of sensors. The result showed relatively reduced baseline drifts in the two types of 3D sensors.Keywords
Funding Information
- Hanwha Systems funded by Agency for Defense Department (UC170020ID)
This publication has 18 references indexed in Scilit:
- A new contactless magneto-LC resonance technology for real-time respiratory motion monitoringSensors and Actuators A: Physical, 2017
- Respiration sensor made from indium tin oxide-coated conductive fabricsJournal of the Korean Physical Society, 2015
- Weft-Knitted Strain Sensor for Monitoring Respiratory Rate and Its Electro-Mechanical ModelingIEEE Sensors Journal, 2014
- Simplified Structural Textile Respiration Sensor Based on Capacitive Pressure Sensing MethodIEEE Sensors Journal, 2014
- Design of a garment-based sensing system for breathing monitoringTextile Research Journal, 2012
- Development of a Respiratory Inductive Plethysmography Module Supporting Multiple Sensors for Wearable SystemsSensors, 2012
- Textile electrodes of jacquard woven fabrics for biosignal measurementThe Journal of the Textile Institute, 2010
- Monitoring of Ventilation During Exercise by a Portable Respiratory Inductive PlethysmographChest, 2005
- Evaluation of Respiratory Inductive PlethysmographyChest, 1997
- Rib cage and abdominal piezoelectric film belts to measure ventilatory airflowJournal of Clinical Monitoring and Computing, 1990