Observation of curative effects of Ex-PRESS and AGV implantation in the treatment of refractory glaucoma
Authors:
Open Access
- 20 March 2018
- journal article
- research article
- Published by Spandidos Publications in Experimental and Therapeutic Medicine
- Vol. 15 (5) , 4419-4425
Abstract
The curative effects of Ex-PRESS implantation and Ahmed glaucoma valve (AGV) implantation in the treatment of refractory glaucoma were compared. A total of 68 patients (76 eyes) with refractory glaucoma treated were randomly divided into Ex-PRESS group and AGV group. Results showed that the intraocular pressure IOP in both Ex-PRESS group and AGV group after operation was significantly decreased compared with that before operation (P0.05). Moreover, the corneal endothelial cell counts of patients in both groups after operation were obviously decreased compared with those before operation (P<0.05). The number of anti-glaucoma drugs applied was decreased from 3.53±0.86 to 0.55±0.60 in Ex-PRESS, and from 3.24±0.88 to 0.89±0.73 in AGV group. At the end of follow-up, the number of anti-glaucoma drugs applied in Ex-PRESS group was smaller than that in AGV group (P0.05). Finally, the incidence rates of postoperative complications and surgical intervention rates had no statistically significant differences between the two groups. Ex-PRESS implantation is a safe and effective treatment for refractory glaucoma, characterized by simple operation, small trauma and less pain, which has an equivalent curative effect to AGV implantation; but its control effect on IOP after operation is superior to that of AGV, and the number of anti-glaucoma drugs applied after operation is small.Keywords
This publication has 22 references indexed in Scilit:
- An Update on Implants for Minimally Invasive Glaucoma Surgery (MIGS)Ophthalmology and Therapy, 2017
- Comparison of trabeculectomy and Ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised studyEye, 2012
- Comparative Study of Encapsulated Blebs Following Ahmed Glaucoma Valve Implantation and Trabeculectomy with Mitomycin-CKorean Journal of Ophthalmology, 2012
- Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucomaClinical Ophthalmology, 2011
- Assessment of Bleb Morphologic Features and Postoperative Outcomes After Ex-PRESS Drainage Device Implantation Versus TrabeculectomyAmerican Journal of Ophthalmology, 2011
- Comparison of Trabeculectomy With Ex-PRESS Miniature Glaucoma Device Implanted Under Scleral FlapJournal of Glaucoma, 2007
- Long-term results of Ahmed glaucoma valve and Molteno implant in neovascular glaucomaEye, 2005
- Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: A clinical pilot studyAmerican Journal of Ophthalmology, 2004
- Aqueous Tube-shunt Implantation and Pars Plana Vitrectomy in Eyes With Refractory GlaucomaAmerican Journal of Ophthalmology, 1993
- New implant for drainage in glaucoma. Clinical trial.British Journal of Ophthalmology, 1969