Intramedullary nailing of extra-articular distal tibial fractures
Authors:
- 1 February 2021
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (2) , 294-298
Abstract
Aims: The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods: A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results: The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The spiral fracture model shortened by a mean of 0.3 mm (SD 0.2), and developed a mean coronal angulation of 2.0° (SD 1.9°) and a mean sagittal angulation of 1.2° (SD 1.1°). On average, 88% of the shortening, 74% of the change in coronal alignment, and 75% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. The oblique fracture model shortened by a mean of 0.2 mm (SD 0.1) and developed a mean coronal angulation of 2.4° (SD 1.6°) and a mean sagittal angulation of 2.6° (SD 1.4°). On average, 44% of the shortening, 39% of the change in coronal alignment, and 79% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. Conclusion: For spiral and oblique fracture patterns, simulated weight-bearing resulted in a clinically acceptable degree of displacement. Most displacement occurred early in the test period, and the rate of displacement decreased over time. Based on this model, we offer evidence that early weight-bearing appears safe for well reduced oblique and spiral fractures, but not in multifragmented patterns that have poor bone contact. Cite this article: Bone Joint J 2021;103-B(2):294–298.Keywords
This publication has 41 references indexed in Scilit:
- Randomized, Prospective Comparison of Plate versus Intramedullary Nail Fixation for Distal Tibia Shaft FracturesJournal of Orthopaedic Trauma, 2011
- Mechanical Evaluation of Large-Size Fourth-Generation Composite Femur and Tibia ModelsAnnals of Biomedical Engineering, 2010
- Radiographic and Clinical Comparisons of Distal Tibia Shaft Fractures (4 to 11 cm Proximal to the Plafond): Plating Versus Intramedullary NailingJournal of Orthopaedic Trauma, 2008
- Minimally Invasive Plating of High-Energy Metaphyseal Distal Tibia FracturesJournal of Orthopaedic Trauma, 2007
- The Effect of Concurrent Fibular Fracture on the Fixation of Distal Tibia Fractures: A Laboratory Comparison of Intramedullary Nails With Locked PlatesJournal of Orthopaedic Trauma, 2007
- Treatment of distal tibial fractures: plate versus nailInternational Orthopaedics, 2006
- Effect of Early Axial Dynamization on Tibial Bone HealingClinical Orthopaedics and Related Research, 2001
- EFFECTS OF AXIAL DYNAMIZATION ON BONE HEALING1993
- Mechanical effects of function on bone healing: Nonweight bearing and exercise in osteotomized ratsActa Orthopaedica, 1991
- EFFECT OF CONTROLLED AXIAL MICROMOVEMENT ON HEALING OF TIBIAL FRACTURESThe Lancet, 1986