On the uncertainties of photon mass energy-absorption coefficients and their ratios for radiation dosimetry
Authors:
- David T BurnsDBDavid T Burns
- Francesc SalvatFSFrancesc Salvat
- 27 March 2012
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (8) , 2117-2136
Abstract
A systematic analysis of the available data has been carried out for mass energy-absorption coefficients and their ratios for air, graphite and water for photon energies between 1 keV and 2 MeV, using representative kilovoltage x-ray spectra for mammography and diagnostic radiology below 100 kV, and for ¹⁹²Ir and ⁶⁰Co gamma-ray spectra. The aim of this work was to establish 'an envelope of uncertainty' based on the spread of the available data. Type A uncertainties were determined from the results of Monte Carlo (MC) calculations with the PENELOPE and EGSnrc systems, yielding mean values for µ(en)/ρ with a given statistical standard uncertainty. Type B estimates were based on two groupings. The first grouping consisted of MC calculations based on a similar implementation but using different data and/or approximations. The second grouping was formed by various datasets, obtained by different authors or methods using the same or different basic data, and with different implementations (analytical, MC-based, or a combination of the two); these datasets were the compilations of NIST, Hubbell, Johns-Cunningham, Attix and Higgins, plus MC calculations with PENELOPE and EGSnrc. The combined standard uncertainty, u(c), for the µ(en)/ρ values for the mammography x-ray spectra is 2.5%, decreasing gradually to 1.6% for kilovoltage x-ray spectra up to 100 kV. For ⁶⁰Co and ¹⁹²Ir, u(c) is approximately 0.1%. The Type B uncertainty analysis for the ratios of µ(en)/ρ values includes four methods of analysis and concludes that for the present data the assumption that the data interval represents 95% confidence limits is a good compromise. For the mammography x-ray spectra, the combined standard uncertainties of (µ(en)/ρ)(graphite,air) and (µ(en)/ρ)(graphite,water) are 1.5%, and 0.5% for (µ(en)/ρ)(water,air), decreasing gradually down to u(c) = 0.1% for the three µ(en)/ρ ratios for the gamma-ray spectra. The present estimates are shown to coincide well with those of Hubbell (1977 Rad. Res. 70 58-81), except for the lowest energy range (radiodiagnostic) where it is concluded that current databases and their systematic analysis represent an improvement over the older Hubbell estimations. The results for (µ(en)/ρ)(graphite,air) for the gamma-ray dosimetry range are moderately higher than those of Seltzer and Bergstrom (2005 private communication).Keywords
This publication has 24 references indexed in Scilit:
- Backscatter factors and mass energy-absorption coefficient ratios for diagnostic radiology dosimetryPhysics in Medicine & Biology, 2011
- Measurement of the x-ray mass energy-absorption coefficient of air using 3 keV to 10 keV synchrotron radiationPhysics in Medicine & Biology, 2006
- A new approach to the determination of air kerma using primary-standard cavity ionization chambersPhysics in Medicine & Biology, 2006
- Review of photon interaction cross section data in the medical and biological contextPhysics in Medicine & Biology, 1999
- Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammographyMedical Physics, 1997
- Introduction to Radiological Physics and Radiation Dosimetry1986
- Photon mass attenuation and energy-absorption coefficientsThe International Journal of Applied Radiation and Isotopes, 1982
- Erratum noticeComputer Physics Communications, 1977
- A multiconfiguration relativistic DIRAC-FOCK programComputer Physics Communications, 1975
- A General Theory of Cavity IonisationBritish Journal of Radiology, 1966