Design of a small animal PET imaging system with 1 microliter volume resolution
Authors:
- M. SchmandMSM. Schmand
- S. SiegelSSS. Siegel
- G.D. HutchinsGHG.D. Hutchins
- 12 July 2004
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (3) , 757-763
Abstract
The design of a new scanner for use in small animal PET imaging is described. The goal is to achieve 1 mm FWHM resolution in each of three orthogonal directions throughout a volume suitable for whole body mouse imaging, roughly 40 mm diameter /spl times/ 80 mm long. Simultaneously, the design should achieve a sensitivity of greater than 5% of all decays from a point source located at the center of the scanner. The scanner uses 12, plane detector banks mounted in a 160 mm diameter ring on a rotating gantry. Each detector bank consists of a 48 /spl times/ 108 array of 20 mm long LSO crystals with an array pitch of 0.87 mm. Each bank uses two Hamamatsu H8500 large-area, multi-anode photomultiplier tubes for fluorescence detection. The detector banks are divided into two sets with the respective lines of response offset by one quarter of the array pitch to give increased sampling density. Tests using a prototype crystal array demonstrate that individual crystals can be resolved. Simulations have been performed to evaluate the performance expected in the complete scanner. With F-18 point sources, the FWHM resolutions in the radial, tangential, and axial directions are less than 1 mm for source positions throughout the desired field of view (FOV). Simultaneously, the detector sensitivity is greater than 7% of all decays for a point source located at the center of the FOV. Results are also presented for simulations using different PET isotopes to investigate the effect of positron range, and for a phantom containing hot spots added to a uniform background to evaluate the scanner performance for an extended object.Keywords
This publication has 17 references indexed in Scilit:
- Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanners without depth-of-interaction capabilityIEEE Transactions on Nuclear Science, 2003
- MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imagingPhysics in Medicine & Biology, 2003
- Performance evaluation of the microPET R4 PET scanner for rodentsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Performance characteristics of micro crystal element (MiCE) detectorsIEEE Transactions on Nuclear Science, 2001
- Performance evaluation of the microPET P4: a PET system dedicated to animal imagingPhysics in Medicine & Biology, 2001
- A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystalsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2001
- Conceptual design of a high-sensitivity small animal PET camera with 4/spl pi/ coverageIEEE Transactions on Nuclear Science, 1999
- A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animalsIEEE Transactions on Nuclear Science, 1999
- Exact and approximate rebinning algorithms for 3-D PET dataIEEE Transactions on Medical Imaging, 1997
- Three-dimensional performance of a small-diameter positron emission tomographPhysics in Medicine & Biology, 1997