Voltage Independent Reactive Current Based Sensor for Static VAr Control Applications
- 5 April 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (9) , 10023-10031
Abstract
The use of renewable energy-based converters is continuously increasing in modern power systems which inject voltage harmonics in the line. In this work, a novel, simple technique based on a binary (on/off) control of an analog switch is proposed to measure reactive current and reactive power. This method eliminates the requirement of finding sin (ϕ) and its multiplication with the current signal in reactive power computation. The proposed transducer gives a dc signal proportional to the reactive current of a power system, i.e., Isin (ϕ), which is suitable for static VAr compensator (SVC) applications. This transducer output is sufficient as the terminal voltage is common for the measurement as well as for the compensation current. Thus, the required current of SVC for compensation is equal to or proportional to Isin (ϕ). Moreover, voltage harmonics are common in a power system. These harmonics affect the measurement of fundamental reactive power. This method eliminates the need of voltage measurement and hence the measurement is independent of harmonics of the voltage, which reduces the measurement error. The proposed method is proved mathematically, and its performance is successfully validated through simulation analysis and hardware implementation. The advantages of the proposed technique are linearity of the transducer output, simple working, inexpensive hardware realization, fast response, and online measurement capability. The response time of the transducer is one cycle of supply voltage which is suitable for SVC applications.Keywords
Funding Information
- Qatar National Research Fund (NPRP grant [13S-0108-200028])
This publication has 26 references indexed in Scilit:
- A Smart Power Meter to Monitor Energy Flow in Smart Grids: The Role of Advanced Sensing and IoT in the Electric Grid of the FutureIEEE Sensors Journal, 2017
- Dynamic Load Balancing and Reactive Power Compensation Switch Embedded in Power MetersIEEE Transactions on Circuits and Systems II: Express Briefs, 2016
- Estimation of the reactive power of corrupted waveforms using the DWT2015
- Embedded Power and Energy Measurement System Based on an Analog MultiplierIEEE Transactions on Instrumentation and Measurement, 2013
- A Low-Cost Fault-Tolerant Real, Reactive, and Apparent Power Measurement Technique Using MicroprocessorIEEE Transactions on Instrumentation and Measurement, 2007
- A Measuring Method of the Single-Phase AC Frequency, Phase, and Reactive Power Based on the Hilbert FilteringIEEE Transactions on Instrumentation and Measurement, 2007
- Thyristor-Based FACTS Controllers for Electrical Transmission Systems2002
- Reactive power measurement using the wavelet transformIEEE Transactions on Instrumentation and Measurement, 2000
- Digital realization of frequency insensitive phase shifter for reactive Var-Hour metersIEEE Transactions on Instrumentation and Measurement, 2000
- Two methods for improved measurements of reactive power and reactive energy insensitive to frequency variationsIEEE Transactions on Instrumentation and Measurement, 1998