Understanding and mitigating overheating and indoor PM 2.5 risks using coupled temperature and indoor air quality models
Open Access
- 13 January 2015
- journal article
- research article
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 36 (2) , 275-289
Abstract
Indoor temperature and air quality in dwellings are closely coupled. Differences between the indoor temperature and the temperature outside and in adjoining zones can influence airflow due to the stack effect, whilst changes in ventilation can cause changes in indoor pollution and temperature. This paper demonstrates the relationship between an indoor air pollutant, PM 2.5 , and temperature in UK domestic building archetypes using the dynamic thermal and contaminant modelling capabilities of EnergyPlus 8.0 under various UK Climate Projections 2009 (UKCP09) scenarios (current, current ‘hot’, 2050 High Emissions and 2050 High Emissions ‘hot’), with both internal and external PM 2.5 sources. Results indicate that flats have 0.7–0.8 times as much outdoor PM 2.5 infiltrating indoors compared to detached dwellings, but 1.8–2.8 times more PM 2.5 from indoor sources. During hot periods, temperature-dependent window opening increases exposure to outdoor PM 2.5 , meaning that as temperatures rises, dwelling occupants will become exposed to relatively higher levels of outdoor PM 2.5 and lower levels of indoor PM 2.5 due to the need to increase dwelling ventilation. The practical implications for government and designers and possible policy implications of this research are discussed. Practical applications: This paper demonstrates how an increase in summertime ventilation is necessary in UK homes to reduce overheating risks due to climate change and energy-efficient building retrofits. This, in turn, will lead to a change in the profile of indoor air pollution exposure, with greater exposure to pollution from outdoor sources and reduced exposure to pollution from indoor sources. Roof insulation and trickle vents reduce overheating risk, whilst increased use of mechanical ventilation heat recovery systems in the UK is encouraged, as it offers the co-benefits of cooling through increased ventilation, energy recovery and the potential to reduce indoor pollution levels.Keywords
This publication has 23 references indexed in Scilit:
- The impact of occupancy patterns, occupant-controlled ventilation and shading on indoor overheating risk in domestic environmentsBuilding and Environment, 2014
- The relative importance of input weather data for indoor overheating risk assessment in dwellingsBuilding and Environment, 2014
- Simulation of pollution transport in buildings: the importance of taking into account dynamic thermal effectsBuilding Services Engineering Research & Technology, 2014
- National survey of summertime temperatures and overheating risk in English homesBuilding and Environment, 2013
- Preventing the overheating of English suburban homes in a warming climateBuilding Research & Information, 2013
- Indoor PM2.5 exposure in London's domestic stock: Modelling current and future exposures following energy efficient refurbishmentAtmospheric Environment, 2012
- Ranking of interventions to reduce dwelling overheating during heat wavesEnergy and Buildings, 2012
- Modelling the relative importance of the urban heat island and the thermal quality of dwellings for overheating in LondonBuilding and Environment, 2012
- Investigating the potential of overheating in UK dwellings as a consequence of extant climate changeEnergy Policy, 2010
- Indoor time–microenvironment–activity patterns in seven regions of EuropeJournal of Exposure Science & Environmental Epidemiology, 2006