Intrarater and interrater reliability of three classifications for scapular dyskinesis in athletes
Open Access
- 27 July 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (7) , e0181518
Abstract
Clinical evaluation of scapular dyskinesis (SD) aims to identify abnormal scapulothoracic movement, underlying causal factors, and the potential relationship with shoulder symptoms. The literature proposes different methods of dynamic clinical evaluation of SD, but improved reliability and agreement values are needed. The present study aimed to evaluate the intrarater and interrater agreement and reliability of three SD classifications: 1) 4-type classification, 2) Yes/No classification, and 3) scapular dyskinesis test (SDT). Seventy-five young athletes, including 45 men and 30 women, were evaluated. Raters evaluated the SD based on the three methods during one series of 8–10 cycles (at least eight and maximum of ten) of forward flexion and abduction with an external load under the observation of two raters trained to diagnose SD. The evaluation protocol was repeated after 3 h for intrarater analysis. The agreement percentage was calculated by dividing the observed agreement by the total number of observations. Reliability was calculated using Cohen Kappa coefficient, with a 95% confidence interval (CI), defined by Kappa coefficient ±1.96 multiplied by the measurement standard error. The interrater analyses showed an agreement percentage between 80% and 95.9% and an almost perfect reliability (k>0.81) for the three classification methods in all the test conditions, except the 4-type and SDT classification methods, which had substantial reliability (k<0.80) in shoulder abduction. Intrarater analyses showed agreement percentages between 80.7% and 89.3% and substantial reliability (0.67 to 0.81) for both raters in the three classifications. CIs ranged from moderate to almost perfect categories. This indicates that the three SD classification methods investigated in this study showed high reliability values for both intrarater and interrater evaluation throughout a protocol that provided SD evaluation training of raters and included several repetitions of arm movements with external load during a live assessment.Keywords
This publication has 21 references indexed in Scilit:
- Reliability of Performance-Based Clinical Measurements to Assess Shoulder Girdle Kinematics and Positioning: Systematic ReviewPhysical Therapy, 2016
- Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic reviewPhysiotherapy Theory and Practice, 2014
- Clinical implications of scapular dyskinesis in shoulder injury: the 2013 consensus statement from the ‘scapular summit’British Journal of Sports Medicine, 2013
- Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic reviewBritish Journal of Sports Medicine, 2012
- Clinical assessment of the scapula: a review of the literatureBritish Journal of Sports Medicine, 2012
- Scapular Dyskinesis and Its Relation to Shoulder InjuryJournal of the American Academy of Orthopaedic Surgeons, 2012
- Current concepts: scapular dyskinesisBritish Journal of Sports Medicine, 2009
- Scapular DysfunctionAthletic Therapy Today, 2006
- Qualitative clinical evaluation of scapular dysfunction: A reliability studyJournal of Shoulder and Elbow Surgery, 2002
- Thoracic position effect on shoulder range of motion, strength, and three-dimensional scapular kinematicsArchives of Physical Medicine and Rehabilitation, 1999