A Multistage Algorithm for ECG Rhythm Analysis During Piston-Driven Mechanical Chest Compressions
- 16 April 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (1) , 263-272
Abstract
Objective: An accurate rhythm analysis during cardiopulmonary resuscitation (CPR) would contribute to increase survival from out-of-hospital cardiac arrest. Piston-driven mechanical compression devices are frequently used to deliver CPR. The objective of this work was to design a method to accurately diagnose the rhythm during compressions delivered by a piston-driven device. Methods: Data was gathered from 230 out-of-hospital cardiac arrest patients treated with the LUCAS 2 mechanical CPR device. The dataset comprised 201 shockable and 844 nonshockable ECG segments, whereof 270 were asystole (AS) and 574 organized rhythm (OR). A multistage algorithm (MSA) was designed, which included two artifact filters based on a recursive least squares algorithm, a rhythm analysis algorithm from a commercial defibrillator, and an ECG-slope based rhythm classifier. Data was partitioned randomly and patient-wise into training (60%) and test (40%) for optimization and validation, and statistically meaningful results were obtained repeating the process 500 times. Results: The mean (standard deviation) sensitivity (SE) for shockable rhythms, specificity (SP) for nonshockable rhythms, and total accuracy of the MSA solution were: 91.7 (6.0), 98.1 (1.1) and 96.9 (0.9), respectively. The SP for AS and OR were 98.0 (1.7) and 98.1 (1.4), respectively. Conclusions: The SE/SP were above the 90/95% values recommended by the American Heart Association for shockable and nonshockable rhythms other than sinus rhythm, respectively.Keywords
Funding Information
- Spanish Ministerio de Economía y Competitividad Project (TEC2015-64678-R)
- Fondo Europeo de Desarrollo Regional
- University of the Basque Country (GIU17/031)
- Basque Government (pre-2016-1-0012)
This publication has 43 references indexed in Scilit:
- Feasibility of automated rhythm assessment in chest compression pauses during cardiopulmonary resuscitationResuscitation, 2013
- Mechanical CPR devices compared to manual CPR during out-of-hospital cardiac arrest and ambulance transport: a systematic reviewScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2012
- The impact of increased chest compression fraction on return of spontaneous circulation for out-of-hospital cardiac arrest patients not in ventricular fibrillationResuscitation, 2011
- Cardiopulmonary resuscitation artefact suppression using a Kalman filter and the frequency of chest compressions as the reference signalResuscitation, 2010
- Shock Advisory System for Heart Rhythm Analysis During Cardiopulmonary Resuscitation Using a Single ECG Input of Automated External DefibrillatorsAnnals of Biomedical Engineering, 2010
- Reduction of CPR artifacts in the ventricular fibrillation ECG by coherent line removalBioMedical Engineering OnLine, 2010
- Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation*Critical Care Medicine, 2008
- Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefactsResuscitation, 2007
- Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECGResuscitation, 2004
- Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithmIEEE Transactions on Biomedical Engineering, 2002