In situ measurement and modeling of biomechanical response of human cadaveric soft tissues for physics-based surgical simulation
- 24 September 2008
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 23 (6) , 1298-1307
Abstract
Background Development of a laparoscopic surgery simulator that delivers high-fidelity visual and haptic (force) feedback, based on the physical models of soft tissues, requires the use of empirical data on the mechanical behavior of intra-abdominal organs under the action of external forces. As experiments on live human patients present significant risks, the use of cadavers presents an alternative. We present techniques of measuring and modeling the mechanical response of human cadaveric tissue for the purpose of developing a realistic model. The major contribution of this paper is the development of physics-based models of soft tissues that range from linear elastic models to nonlinear viscoelastic models which are efficient for application within the framework of a real-time surgery simulator. Methods To investigate the in situ mechanical, static, and dynamic properties of intra-abdominal organs, we have developed a high-precision instrument by retrofitting a robotic device from Sensable Technologies (position resolution of 0.03 mm) with a six-axis Nano 17 force-torque sensor from ATI Industrial Automation (force resolution of 1/1,280 N along each axis), and used it to apply precise displacement stimuli and record the force response of liver and stomach of ten fresh human cadavers. Results The mean elastic modulus of liver and stomach is estimated as 5.9359 kPa and 1.9119 kPa, respectively over the range of indentation depths tested. We have also obtained the parameters of a quasilinear viscoelastic (QLV) model to represent the nonlinear viscoelastic behavior of the cadaver stomach and liver over a range of indentation depths and speeds. The models are found to have an excellent goodness of fit (with R 2 > 0.99). Conclusions The data and models presented in this paper together with additional ones based on the principles presented in this paper would result in realistic physics-based surgical simulators.Keywords
This publication has 41 references indexed in Scilit:
- A comparison of some model order reduction methods for fast simulation of soft tissue response using the point collocation-based method of finite spheresEngineering with Computers, 2008
- A robotic indenter for minimally invasive measurement and characterization of soft tissue responseMedical Image Analysis, 2007
- Tissue consistency perception in laparoscopy to define the level of fidelity in virtual reality simulationSurgical Endoscopy, 2006
- What can the operator actually feel when performing a laparoscopy?Surgical Endoscopy, 2004
- Imaging of the elastic properties of tissue—A reviewUltrasound in Medicine & Biology, 1996
- Biomechanics: Mechanical Properties of Living Tissues, 2nd ed.Journal of Applied Mechanics, 1994
- Some Forms of the Strain Energy Function for RubberRubber Chemistry and Technology, 1993
- Biology of CollagenJournal of Biomechanical Engineering, 1982
- Large deformation isotropic elasticity – on the correlation of theory and experiment for incompressible rubberlike solidsProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1972
- Large elastic deformations of isotropic materials IV. further developments of the general theoryPhilosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences, 1948