Multiview-based computer-aided detection scheme for breast masses
Authors:
- Bin ZhengBZBin Zheng
- Joseph K. LeaderJLJoseph K. Leader
- Gordon S. AbramsGAGordon S. Abrams
- Amy H. LuALAmy H. Lu
- Luisa P. WallaceLWLuisa P. Wallace
- Glenn S. MaitzGMGlenn S. Maitz
- David GurDGDavid Gur
- 16 August 2006
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 33 (9) , 3135-3143
Abstract
In this study, we developed and tested a new multiview-based computer-aided detection (CAD) scheme that aims to maintain the same case-based sensitivity level as a single-image-based scheme while substantially increasing the number of masses being detected on both ipsilateral views. An image database of 450 four-view examinations (1800 images) was assembled. In this database, 250 cases depicted malignant masses, of which 236 masses were visible on both views and 14 masses were visible only on one view. First, we detected suspected mass regions depicted on each image in the database using a single-image-based CAD. For each identified region (with detection score > or = 0.55), we then identified a matching strip of interest on the ipsilateral view based on the projected distance to the nipple along the centerline. By lowering CAD operating threshold inside the matching strip, we searched for a region located inside the strip and paired it with the original region. A multifeature-based artificial neural network scored the likelihood of the paired "matched" regions representing true-positive masses. All single (unmatched) regions except for those either with very high detection scores (> or = 0.85) or those located near the chest wall that cannot be matched on the other view were discarded. The original single-image-based CAD scheme detected 186 masses (74.4% case-based sensitivity) and 593 false-positive regions. Of the 186 identified masses, 91 were detected on two views (48.9%) and 95 were detected only on one view (51.1%). Of the false-positive detections, 54 were paired on the ipsilateral view inside the corresponding matching strips and the remaining 485 were not, which represented 539 case-based false-positive detections (0.3 per image). Applying the multiview-based CAD scheme, the same case-based sensitivity was maintained while cueing 169 of 186 masses (90.9%) on both views and at the same time reducing the case-based false-positive detection rate by 23.7% (from 539 to 411). The study demonstrated that the new multiview-based CAD scheme could substantially increase the number of masses being cued on two ipsilateral views while reducing the case-based false-positive detection rate.Keywords
Funding Information
- National Institutes of Health
This publication has 26 references indexed in Scilit:
- Computer-aided Detection in the United Kingdom National Breast Screening Programme: Prospective StudyRadiology, 2005
- A Computer-Aided Detection System for the Evaluation of Breast Cancer by Mammographic Appearance and Lesion SizeAmerican Journal of Roentgenology, 2005
- Computer-aided Detection Performance in Mammographic Examination of Masses: AssessmentRadiology, 2004
- Computer-Aided Detection Schemes: The Effect of Limiting the Number of Cued Regions in Each CaseAmerican Journal of Roentgenology, 2004
- Changes in Breast Cancer Detection and Mammography Recall Rates After the Introduction of a Computer-Aided Detection SystemJNCI: Journal of the National Cancer Institute, 2004
- Improvement in Sensitivity of Screening Mammography with Computer-Aided Detection:A Multiinstitutional TrialAmerican Journal of Roentgenology, 2003
- Computer-aided Detection: There Is No Free LunchRadiology, 2001
- Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast CenterRadiology, 2001
- Potential Contribution of Computer-aided Detection to the Sensitivity of Screening MammographyRadiology, 2000
- Computer screening of xeromammograms: A technique for defining suspicious areas of the breastComputers and Biomedical Research, 1979