Seepage through a Levee
Authors:
- 1 March 2005
- journal article
- Published by American Society of Civil Engineers (ASCE) in International Journal of Geomechanics
- Vol. 5 (1) , 74-79
Abstract
A steady-state two-dimensional unconfined flow through a homogeneous levee with a horizontal toe drain resting on an impervious base has been analyzed. Unlike in Kozeny’s method, the hydraulic resistance of the soil in a levee bounded by an equipotential parabolic surface and the straight upstream sloping face has been considered in the computation of the seepage and location of the phreatic line. The appropriate position of a filter in the levee is suggested to contain capillary rise well within the downstream sloping surface. The seepage through a zoned levee with an upstream rock fill part and a horizontal toe drain resting on an impervious base is also analyzed.Keywords
This publication has 3 references indexed in Scilit:
- A practical method for solving free-surface seepage problemsComputers and Geotechnics, 2002
- Application and validation of a numerical model of flow through embankment dams with fractures: comparisons with experimental dataCanadian Geotechnical Journal, 1999
- Discussion: On the variable mesh finite elements analysis of unconfined seepage problemsGéotechnique, 1990