Molecularly Imprinted Polymers Based on Iodinated Monomers for Selective Room-Temperature Phosphorescence Optosensing of Fluoranthene in Water
Authors:
- José M. Costa-FernándezJosé M. Costa-Fernández
- Rosario PereiroRosario Pereiro
- Alfredo Sanz-MedelASAlfredo Sanz-Medel
- Alfonso SalinasASAlfonso Salinas
- Antonio SeguraAntonio Segura
- Alberto Fernández-GutiérrezAFAlberto Fernández-Gutiérrez
- Alfredo BallesterosABAlfredo Ballesteros
- José M. GonzálezJGJosé M. González
- 4 October 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (21) , 7005-7011
Abstract
Aiming at enhancing the advantages of traditional molecularly imprinted polymers (MIPs) for chemical sensing, a new MIP design approach introducing an internal heavy atom in their polymeric structure is described. Based on the heavy-atom effect, the novel polymer allows one to perform room-temperature phosphorescence (RTP) transduction of the analyte. The synergic combination of a tailor-made MIP recognition with a selective RTP detection is a novel concept for optosensing devices which is assessed here for simple and highly selective determination of trace amounts of fluoranthene in water. The noncovalent MIP was synthesized using the laboratory-synthesized tetraiodobisphenol A as one of the polymeric precursors and fluoranthene as template. In the presence of an oxygen scavenger, the iodide included in the polymeric structure induced efficient RTP emission from the analyte, once recognized by the MIP. The developed optosensing system has demonstrated a high specificity for fluoranthene against other polycyclic aromatic hydrocarbons. Detection limit for the target molecule was 35 ng/L (5-mL sample injections), and the linear range extended above 100 μg/L of the analyte. The polymer can be easily regenerated for subsequent sample injections (at least up to 450 cycles) with acetonitrile. The synthesized sensing material showed good stability for at least 6 months after preparation. The feasibility of monitoring fluoranthene in real samples was successfully evaluated through the analysis of five spiked river water samples.Keywords
This publication has 22 references indexed in Scilit:
- Polymer film sensor for sampling and remote analysis of polycyclic aromatic hydrocarbons in clear and turbid aqueous environmentsAnalytica Chimica Acta, 2004
- Heavy atom induced room temperature phosphorescence: a tool for the analytical characterization of polycyclic aromatic hydrocarbonsAnalytica Chimica Acta, 2004
- Evidence for shape selectivity in non-covalently imprinted polymersAnalytica Chimica Acta, 2004
- Novel stereoselective molecularly imprinted polymers via ring-opening metathesis polymerisationAnalytica Chimica Acta, 2004
- Highly sensitive and selective fluorescence optosensor to detect and quantify benzo[a]pyrene in water samplesAnalytica Chimica Acta, 2003
- Comparison of immunoassay and gas chromatography–mass spectrometry for measurement of polycyclic aromatic hydrocarbons in contaminated soilAnalytica Chimica Acta, 2003
- Spectrochemical investigations in molecularly organized solvent media: Evaluation of nitromethane as a selective fluorescence quenching agent for alternant PAHs dissolved in micellar solvent mediaAnalytica Chimica Acta, 1996
- Development of a Room-Temperature Phosphorescence Fiber-Optic SensorAnalytical Chemistry, 1996
- Gasoline engine exhaust analysis using constant energy synchronous luminescence spectrometryAnalytical Chemistry, 1986
- Room-temperature phosphorescence, sensitized phosphorescence and fluorescence of licit and illicit drugs enhanced by organized mediaAnalytica Chimica Acta, 1985