Fabrication of high-strength unsupported metal membranes

Authors:

Abstract
Metal membranes ?1 μm thick would be useful as diaphragms for capacitance manometers and acoustic transducers, as x-ray windows, and as deformable mirrors in optical systems. The high strength-to-density to Ti makes that metal particularly suitable for fast-response deformable membranes. Ti films 1/4–2 μm thick and 2–12 cm in diameter were vacuum-deposited at 20–100 Å/s from an electron-beam source at 2×10−7 Torr onto Corning 0317 glass substrates which were held at 500°C by contacting with Ga to a Ti heating block. These substrates are very smooth and match the thermal expansion of Ti to a few percent. Pre-evaporation of a 300 Å thick CaF2 parting layer allowed membrane removal by water-assisted peeling. Pressure testing showed membranes to have bulk tensile strength of 4.6–6.2×109 dyn/cm2 (68–92 Kpsi) and to behave elastically. They could be mounted under high tension by heating while clamped to a high thermal expansion coefficient Nylon flange.