Deep‐learning‐assisted algorithm for catheter reconstruction during MR‐only gynecological interstitial brachytherapy
Authors:
Open Access
- 10 December 2021
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (2) , e13494
Abstract
Magnetic resonance imaging (MRI) offers excellent soft‐tissue contrast enabling the contouring of targets and organs at risk during gynecological interstitial brachytherapy procedure. Despite its advantage, one of the main obstacles preventing a transition to an MRI‐only workflow is that implanted plastic catheters are not reliably visualized on MR images. This study aims to evaluate the feasibility of a deep‐learning‐based algorithm for semiautomatic reconstruction of interstitial catheters during an MR‐only workflow. MR images of 20 gynecological patients were used in this study. Note that 360 catheters were reconstructed using T1‐ and T2‐weighted images by five experienced brachytherapy planners. The mean of the five reconstructed paths were used for training (257 catheters), validation (15 catheters), and testing/evaluation (88 catheters). To automatically identify and localize the catheters, a two‐dimensional (2D) U‐net algorithm was used to find their approximate location in each image slice. Once localized, thresholding was applied to those regions to find the extrema, as catheters appear as bright and dark regions in T1‐ and T2‐weighted images, respectively. The localized dwell positions of the proposed algorithm were compared to the ground truth reconstruction. Reconstruction time was also evaluated. A total of 34 009 catheter dwell positions were evaluated between the algorithm and all planners to estimate the reconstruction variability. The average variation was 0.97 ± 0.66 mm. The average reconstruction time for this approach was 11 ± 1 min, compared with 46 ± 10 min for the expert planners. This study suggests that the proposed deep learning, MR‐based framework has potential to replace the conventional manual catheter reconstruction. The adoption of this approach in the brachytherapy workflow is expected to improve treatment efficiency while reducing planning time, resources, and human errors.Keywords
This publication has 31 references indexed in Scilit:
- Clinical outcomes of definitive chemoradiation followed by intracavitary pulsed-dose rate image-guided adaptive brachytherapy in locally advanced cervical cancerGynecologic Oncology, 2015
- Development and evaluation of an automatic interstitial catheter digitization tool for adaptive high-dose-rate brachytherapyBrachytherapy, 2015
- Review of advanced catheter technologies in radiation oncology brachytherapy proceduresCancer Management and Research, 2015
- Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking systemMedical Physics, 2015
- A practical MRI-based reconstruction method for a new endocavitary and interstitial gynaecological templateJournal of Contemporary Brachytherapy, 2015
- Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostateBrachytherapy, 2014
- Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group: Considerations and pitfalls in commissioning and applicator reconstruction in 3D image-based treatment planning of cervix cancer brachytherapyRadiotherapy and Oncology, 2010
- Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancerRadiotherapy and Oncology, 2009
- Physics Contributions and Clinical Outcome With 3D-MRI–Based Pulsed-Dose-Rate Intracavitary Brachytherapy in Cervical Cancer PatientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Consequences of random and systematic reconstruction uncertainties in 3D image based brachytherapy in cervical cancerRadiotherapy and Oncology, 2008